Controls and displays, Command station cs 5800 and cs 9800, Operation – Lenze CS9800 Operating Instructions User Manual

Page 48

Advertising
background image

Operation

Controls and displays
Command Station CS 5800 and CS 9800

7

l

48

BA_CSx8xx EN 3.0

7.2

Controls and displays

7.2.1

Command Station CS 5800 and CS 9800

-

F3

Fail

Power

F1

+

F2

Status

1
2

0

4

3

CS57x0−022

Pos. Designation

Function

Standard mode

Service mode

Switch on mode:

Press "

[" for 4 s

Switch off mode:

Press "

[" or wait for 35 s

0 Display

Application−dependent

1 Status LEDs

Power (green):

l

Is ON when the supply voltage is present.

Fail (red):

l

Is On when a power supply failure has occurred.

l

Is blinking when the screen signal is missing.

Status (yellow):

l

Application−dependent

2 Function keys

F1 ... F3: Send key code for Shift−F1 ...
Shift−F3

Tool: Application−dependent
+: Increase screen brightness
−: Reduce screen brightness

3 Reset button

Reset PC (restart)

4 Status LEDs

Error (red):

l

Is lit if a power supply failure has occurred.

l

Is blinking when the screen signal is missing.

HD (yellow):

l

Indicates access to a storage medium.

Power (green):

l

Is lit when the supply voltage is present.

l

Flashes (

−−−

−−−

) in the case of a hardware error.

l

Is blinking (

−−

−−

) when the ACU UPS (optional) is being charged.

l

Is blinking (

−−

−−

−−

−−

) when there is a supply voltage failure and the device is being

supplied by the ACU UPS.

l

Is blinking (

) when the supply voltage of the ACU UPS is too low (e.g.

rechargeable battery is empty or missing).

l

Blinks 4 x per second if the ACCU−PACK causes a short circuit or if the CAPS−PACK
is completely discharged.

Advertising
This manual is related to the following products: