General data and operating conditions

4

l

27

BA_CSx8xx EN 3.0

Operating conditions

Mounting conditions

Mounting place

Stand−alone operator console for support arm mounting or
direct fixing to a wall, protected against direct solar radiation

Ambient conditions

Climatic

Storage

−10 ... +60 °C

Transport

−10 ... +60 °C

Operation

Depending on the equipment (

^ 27)

Relative humidity

10 ... 90 %, non−condensing

Site altitude

StoragetTransport

< 12000 m amsl

Operation

< 3000 m amsl

Chemical resistance

Decor film

DIN 42115

Touch/display

Mechanical load capacity

Decor film

DIN 42115

max. 100 N

Touch/display

Switching element

)

Note!

The failure probability of an electronic component increases with the ambient
temperature to which the component is subjected. Regarding the
serviceability and reliability, particular attention should be paid to the cooling
of the device. For every application, you should take care to keep the heating
of the device as low as possible.

Permissible ambient temperatures

Standard device

l

With standard hard
disk

l

With hard disk for
continuous operation
(24/7)

1)

l

With hard disk for
extended temperature
range

l

Up to 1 GB RAM

l

With CF card

Processor

[°C]

Intel

â Atomä N270,

1.6 GHz

5 ... 40

5 ... 45

2)

0 ... 45

2)

1)

We recommend to replace the hard disk after 30 000 hours of operation or after five years at the latest.

2)

Systems in accordance with UL

: 0 ... 40

°C