Command station cs 5850, Operation, Controls and displays command station cs 5850 – Lenze CS9800 Operating Instructions User Manual

Page 50: Home, Pg dn, Pg up end status power fail, Is on when a power supply failure has occurred, Is lit if a power supply failure has occurred, Is lit when the supply voltage is present, Flashes

Advertising
background image

Operation

Controls and displays
Command Station CS 5850

7

l

50

BA_CSx8xx EN 3.0

7.2.3

Command Station CS 5850

Q

+

R

F1

F2

F5

-

S

T

F3

F4

@

\

Z

F11

F10

Y

X

F9

F8

F12

W

V

U

F7

F6

Shift

Alpha

Bs

Space

Enter

Esc

Del

Ins

Menu

Alt

Ctrl

Home

1

I

0

M

4

E

7

A

Pg Dn

*

3

J

K

L

/

,

N

O

P

Pg Up

End

Status

Power

Fail

2

.

+

6

F

G

H

-

9

B

C

D

5

8

6

7

9

2

1

0

4

3

CS57x0−024

Pos. Designation

Function

Standard mode

Alpha mode

Service mode

Switch on mode:

Press "alpha key" (LED is on)

Press "menu key"

Switch off mode:

Press "alpha key" (LED is off)

Press "menu key" or wait for
35 s

0 Display

Application−dependent

1 Status LEDs

Power (green):

l

Is ON when the supply voltage is present.

Fail (red):

l

Is ON when a power supply failure has occurred

l

Is blinking when the screen signal is missing.

Status (yellow):

l

Indicates access to a storage medium.

2 Function keys F1 ... F12: Send key code for

Shift−F1 ... Shift−F12

F1 ... F12: Send key codes for
"Q" ... "@"

Tool: Application−dependent
+: Increase screen brightness
−: Reduce screen brightness

3 Reset button Reset PC (restart)
4 Status LEDs

Error (red):

l

Is lit if a power supply failure has occurred;

l

Is blinking when the screen signal is missing.

HD (yellow):

l

Indicates access to a storage medium.

Power (green):

l

Is lit when the supply voltage is present.

l

Flashes (

−−−

−−−

) in the case of a hardware error.

l

Is blinking (

−−

−−

) when the ACU UPS (optional) is being charged.

l

Is blinking (

−−

−−

−−

−−

) when there is a supply voltage failure and the device is being supplied

by the ACU UPS.

l

Is blinking (

) when the supply voltage of the ACU UPS is too low (e.g. rechargeable

battery is empty or missing).

l

Blinks 4 x per second if the ACCU−PACK causes a short circuit or if the CAPS−PACK is
completely discharged.

6 Numeric

keypad

Send key codes for "0" ... "9"
and calculation operators

Send key codes for "A" ... "P"

Functionality same as in
standard/alpha mode

7 Cursor keys

Without "Shift" key: Move cursor/marker in steps and set
tab
With "Shift" key: Move cursor/marker to the beginning/end
or page by page

Functionality same as in
standard/alpha mode

9 Control keys

Standard functions of a MF2 keyboard
(For "alpha" and "menu" see "Switch on/off mode")

Functionality same as in
standard/alpha mode

Advertising
This manual is related to the following products: