Safety instructions – Lenze CPC 2800 Mounting Instructions User Manual

Page 17

Advertising
background image

Safety instructions

Safety instructions for the installation according to UL

2

l

17

MA_CPCx8xx DE/EN/FR/ES/IT 2.0

2.2

Safety instructions for the installation according to UL

Original − English

Approval

Underwriter Laboratories (UL), UL508 and CSA C22.2 No. 142−M1987, (UL File
Number E236341)

Ratings

ƒ

Input 18 ... 30 V DC , max. 4 A

ƒ

ACCU−Pack and CAPS−Pack: max 0.6 A

ƒ

Max. ambient temperature 50 °C.

ƒ

Optional communication ratings:

RS232−Connection: max. 3 A

USB−Connection: max. 1 A

PS/2−Connection: max. 1 A

LAN−Connection: Standard ISDN or RJ45

DVI−Connection: max. 1 A

J

Warnings!

Field Wiring Markings

Wiring Terminal MSTB 2,5/3−STF−5,08:

ƒ

Use copper wire only.

ƒ

AWG 18 ... AWG 12 (0.82 mm

2

... 3.3 mm

2

)

ƒ

Torque 5...7 lb−in (0.5 ... 0.6 Nm)

Battery

ƒ

Replace battery with any from the list below, Part No. CR 2450
only. Use of another battery may present a risk of fire or
explosion.
Recommended CR2450 (R/C, BBVC2) types:
Renata Part.no. CR2450N, Sony Corp. part no. CR2450B, Toshiba
part no. CR2450, Varta part no. CR2450, Matsushita part no.
CR2450

ƒ

Battery may explode if mistreated. Do not recharge, disassemble,
dispose of in fire or heat above 100 °C (212 °F).

ƒ

Dispose of used battery according to the regulation of recycling
or waste.

Advertising