Safety instructions – Lenze MP 9000 DVI Operating Instructions User Manual

Page 12

Advertising
background image

Safety instructions

Safety instructions for the installation according to UL

2

l

12

BA_MP9000DVI DE 4.0

2.3

Safety instructions for the installation according to UL

Original − English

Approval

Underwriter Laboratories (UL), UL508 and CSA C22.2 No. 142−M1987, (UL File Number
E236341)

Ratings

ƒ

Input 24 V DC, 65 W

ƒ

For use on an isolated power supply rated 24V DC 4A max.

ƒ

Max. ambient temperature 40°C

ƒ

Max. surrounding temperature 50 °C

ƒ

Optional communication ratings:
– RS232−Connection (APL and DPL version only): max. 3 A
– USB−Connection (DVI version only): max. 1 A
– PS/2−Connection: max. 1 A
– VGA−Connection (APL version only): max. 4 A
– FBAS−Connection (APL version only): max. 4 A
– DVI−Connector (DVI version only): max. 4 A
– DPL−Connection (DVI version only): max. 4 A
– External Power Supply for DVI/USB Extender: max. 4 A
– Video−DSUB Connection for DVI/USB Extender: max. 4 A
– Data−DSUB Connection for DVI/USB Extender: max. 4 A

ƒ

Environmental ratings: If these devices are mounted into a door or front cover of an
enclosure: Type 1 Enclosure.

O

Warnings!

Conditions of acceptability

ƒ

These devices are for Type 1 front panel mounting only.

ƒ

The external power supply connection is suitable for field wiring. An isolated
power supply rated 24 V DC, 4 A max. must be used.

Field Wiring Markings
Wiring Terminal MSTB 2,5/3−STF−5,08:

ƒ

Use Copper Wire only.

ƒ

AWG 18 ... AWG 12 (0.82 mm

2

... 3.3 mm

2

)

ƒ

Torque 5...7 lb−in (0.5 ... 0.6 Nm)

Advertising