Electrical installation

Connecting the supply and peripheral devices
Terminal diagram supply

6

l

30

BA_MP9000DVI DE 4.0

6.3

Connecting the supply and peripheral devices

6.3.1

Terminal diagram supply

L1

N

PE

L1 N

+

0V

+24

+

~

=

0 V PE +24 V

+

0

1

F

S

MP9000DVI−006

0 Monitor panel

1 Power supply unit

)

Note!

Observe the max. permissible input voltage.
Professionally fuse the device on the input side against voltage variations and
voltage peaks.

6.3.2

24 V connection

Description

Connection type

Cable type

0V

U

DC 24 V connection

3−pole Phoenix Combicon

socket

Cable (conductor

cross−section max. 2.5 mm

2

)

with Phoenix Combicon plug,

MSTB 2.5 / 3−STF−5.08

IPC001

PE connection

M4 threaded bolt

Separate earthing conductor

(min. 2.5 mm

2

) with ring

cable lug

IPC001