Safety instructions

Residual hazards

2

l

33

EDK84AZESxx DE/EN/FR/ES/IT 4.0

(

Stop!

Dangerously high temperatures

The filter is not protected against mains phase failure. In the event
of a mains phase failure, the filter may become very hot.

Possible consequences:

ƒ

Destruction of the device.

ƒ

Smouldering or open fire.

Protective measures:

ƒ

Change the setting for code C00565 from "Warning" to "Fault" or

ƒ

select a wiring for the bMctrlMainsFault status output
(LS_DeviceMonitor) system block which causes the system to
shutdown within one minute if said output is set to HIGH.

O

Warnings!

Conditions of Acceptability:

ƒ

These devices shall be used within their Recognized ratings as
described in the ratings section.

ƒ

The suitability of the mounting means is to be determined in the
end use application.

ƒ

These devices have been evaluated for factory wiring only.

ƒ

These devices have been investigated for use in a Pollution
Degree 2 environment.

ƒ

These devices are to be installed in a suitable end−product
enclosure.