12 diagnostics, 6 system error messages 192 – Lenze EtherCAT Controller-based Automation User Manual

Page 192

Advertising
background image

12

Diagnostics

12.6

System error messages

192

Lenze · Controller-based Automation · EtherCAT® Communication Manual · DMS 6.4 EN · 04/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5529

... (...): CoE receive WKC error. Command: ..., logic/physical

address: 0x..., WKC act/set=.../...

CAN over EtherCAT: Error during initialisation command for ’CoE

Receive Request’

One or several slaves have not processed a command.

5530

... (...): FoE receive WKC error. Command: ..., logic/physical

address: 0x..., WKC act/set=.../...

File over EtherCAT: Error during initialisation command for ’FoE

Receive Request’

One or several slaves have not processed a command.

5531

... (...): SoE receive WKC error. Command: ..., logic/physical

address: 0x..., WKC act/set=.../...

Sercos over EtherCAT: Error during initialisation command for

’SoE Receive Request’

One or several slaves have not processed a command.

5532

... (...): EoE send WKC error. Command: ..., logic/physical address:

0x..., WKC act/set=.../...

Ethernet over EtherCAT: Error during initialisation command for

’EoE Send Request’

One or several slaves have not processed a command.

5533

... (...): CoE send WKC error. Command: ..., logic/physical address:

0x..., WKC act/set=.../...

CAN over EtherCAT: Error during initialisation command for ’CoE

Send Request’

One or several slaves have not processed a command.

5534

... (...): FoE send WKC error. Command: ..., logic/physical address:

0x..., WKC act/set=.../...

File over EtherCAT: Error during initialisation command for ’FoE

Send Request’

One or several slaves have not processed a command.

5535

... (...): SoE send WKC error. Command: ..., logic/physical address:

0x..., WKC act/set=.../...

Sercos over EtherCAT: Error during initialisation command for

’SoE Send Request’

One or several slaves have not processed a command.

5541

... (...): Error at response to Init command - no response. State

change=’...’

Slave does not respond to Init command

5542

... (...): Error at response to Init command - validation error. State

change=’...’

Slave does not respond correctly to Init command

5543

... (...): Error at response to Init command - failed. State

change=’...’

Init command cannot be written to slave

5544

...: Error at response to master init command - no response. State

change=’...’

Slaves do not respond to Init command (broadcast)

5545

...: Error at response to master init command - validation error.

State change=’...’

Slaves do not respond correctly to Init command (broadcast)

5546

... (...): EtherCAT command ... is missing in the Ethernet frame.

Index of the missing command in the Ethernet frame=...

Internal error

5547

... (...): Mailbox init command timeout. Current state change of

the slave=’...’

Time-out during mailbox initialisation in the case of a state

change

5549

...: Ethernet cable is connected

Ethernet cable is connected again (link-up available)

5550

...:Ethernet cable is not connected

Ethernet cable is not connected (no link-up available)

5551

...: Timeout for cyclical commands. Time between transmission

processes too long

Internal error

5552

...: Redundant operation. Ethernet cable missing at the 2.

EtherCAT interface

Lenze controller does not support redundancy.

5554

... (...): Slaves signals error. AL status: '...' (0x...), AL status code: '...'

(0x...)

Slave indicates an error.

AL status and AL status code are slave-specific.

5555

... (...): Communication to device interrupted

Connection to slave is interrupted. The slave does not respond or

is no longer available.

5557

...: DC slaves ’in-sync’. Deviation ... ns

Information that the DC deviation is within the permissible

limits (standard 8 μs).

5558

...: DC slaves ’out-of-sync’. Deviation ... ns

Information that the DC deviation is not within the permissible

limits (standard 8 μs).

5562

...: Client registration lost

Internal error

5704

...: Connection was changed: connection is established

Internal information

5705

...: Connection was changed. Cookie: 0x... cause: ... (0x...)

Internal information

5706

...: Client was registered by cookie 0x... instance 0x... Id 0x...

result ...

Internal information

5707

...: Client was deleted by cookie 0x... instance 0x... Id 0x... result ... Internal information

5708

...: Unknown registration: 0x...

Internal error: Master outputs unknown message.

5719

... (...): Slave has incorrect status. Status set/act ’...’/’...’

Slave is not in expected status:

’req’ is the requested status and ’act’ the current status

5729

...: RAP - invalid parameter size for ...

Internal error

5730

...: RAP - Marshaling error. Cookie: 0x..., Command: 0x..., Cause:

... (0x...), Protocol Header: 0x...

Internal error

5731

...: ... could not be included in queue (missing calls of the

ProcessNotificationJobs)

Internal error

Error no.

Message text in the Lenze Controller logbook

Description

Advertising