4 adding/removing user data, Adding/removing user data, E 28) – Lenze Card File Handler User Manual

Page 28

Advertising
background image

Card File Handler

Operation

Editing drive sets

28

1.1 EN

L

Removing a GDC parameter set file

S

How to remove a GDC parameter set file from a drive set:

1. Select the drive set from which you want to remove the GDC parameter set file

from the archive tree.

2. Go to the Dialog area and click the

icon to the right of the GDC parameter set

file text field.

3. You will be asked if you really want to remove the GDC parameter set file. Confirm

this question with OK.

3.3.4

Adding/removing user data

Adding user data
After a DDS binary file has been added to the drive set, you can add an *.lc9 file including

motion profiles or cam profile data to the drive set (option).

S

How to add user data to a drive set:

1. Select the drive set to which you want to add the user data from the archive tree.

2. Go to the Dialog area and click the

icon to the right of the User data text field.

• The function can only be activated if you have already added a DDS binary file

to the drive set.

3. Go to the Open user data dialog box, select the corresponding *.lc9 file and click

Open.

Note!

Ensure that the user data match the program because this will not be checked

automatically.
In the Drive PLC Developer Studio, you can use the CAM Support to add cam

profile data to your project. For detailed information, please read the

documentation for the Drive PLC Developer Studio.

Show/Hide Bookmarks