L. Torch cuts but cuts are of low quality

1. Amperage control set too low, increase current setting.

2. Torch is being moved too fast across workpiece, reduce cutting speed.

3. Excessive oil or moisture in torch, hold torch 1/8 inch (3 mm) from clean surface while

purging and observe oil or moisture buildup (do not activate torch). If there are contaminants

in the gas, additional filtering may be needed.