MAG.LAYERS

GMPI-201209-F1 Series

Vibration

L/Lo

≦±

5%

There shall be no mechanical damage.

The sample shall be soldered onto the
printed circuit board and when a vibration
having an amplitude of 1.52mm and a
frequency of from 10 to 55Hz/1 minute
repeated should be applied to the 3
directions (X,Y,Z) for 2 hours each.

Drop shock

No apparent damage

Dropped onto printed circuit board from
100cm height three times in x, y, z
directions. The terminals shall be protected.

CLIMATIC TEST

ITEM

SPECIFICATION

TEST CONDITION

Thermal Shock
(Temperature Cycle)

Temperature: -40

,85

for 30 minutes

each, 100 cycles.

Humidity Resistance

Temperature : 40

Humidity: 95% RH
Time: 1000

±

12 HOURS

High Temperature
Resistance

Temperature: 85

±

2

Time: 1000

±

12 hours

Low Temperature
Resistance

No mechanical damage.
Inductance shall be within

±

5% of the initial

value, and Q (shall be) within

±

30% of the initial

value.

Temperature : -40

±

2

Time: 1000

±

12 hours

1. Operating Temperature Range: -55

TO +125

2. Storage Condition: The temperature should be within -40

~85

and humidity should be less than

75% RH. The product should be used within 6 months from the time of delivery.

Advertising