Mechanical Performance Test

ITEM

SPECIFICATION

TEST CONDITION

Solderability

More than 90% of the terminal electrode shall
be covered with fresh solder.

Solder: 96.5Sn-3.0Ag-0.5Cu
Solder Temperature: 245

±

5

Flux: Rosin
Dip Time: 3

±

1 Seconds

Soldering Heat
Resistance

The chip shall not crack.
More than 75% of the terminal electrode shall
be covered with solder.

Solder temperature : 260

±

5

Flux: Rosin
Dip time: 10

±

1 seconds

TYPE

W(KGF)

TIME (SEC)

GMLB-2012-M4

0.2

10

±

2

Terminal Strength

The terminal electrode shall not be broken off
nor the ferrite damaged.

W

GMLB-3216-M4

0.5

10

±

2

TYPE

A(MM)

P(KGF)

GMLB-2012-M4

1.74

0.2

Bending Strength

No mechanical damage.

The ferrite shall not be damaged.

A

Chip

P

1.0

R0.5

GMLB-3216-M4

2.0

2.0

Bending Test

Appearance: No damage

Substrate: PCB(100mm

×

40mm

×

1.6mm)

Solder: Reflow
Speed of Applying Force: 0.5mm / s
Deflection: 2mm
Hold Duration: 30 s

Vibration

Impedance shall be within

±

20% of the initial

value.

There shall be no mechanical damage.

The sample shall be soldered onto the printed
circuit board and when a vibration having an
amplitude of 1.52mm and a frequency of from 10
to 55Hz/1 minute repeated should be applied to
the 3 directions (X,Y,Z) for 2 hours each.

Drop shock

No apparent damage

Dropped onto printed circuit board from 100cm
height three times in x, y, z directions. The
terminals shall be protected.

Climatic test

ITEM

SPECIFICATION

TEST CONDITION

Thermal Shock
(Temperature Cycle)

Temperature cycle : -55

~125

for 30

minutes each.
Total: 100 cycles.

Humidity Resistance

Temperature : +60

Humidity: 90% RH
Applied current: rated current
Time: 1000

±

12 hours

High Temperature
Resistance

Temperature : 80

Applied current: rated current
Time: 1000

±

12 hours

Low Temperature
Resistance

Impedance shall be within

±

20% of the initial

value.

Temperature : -40

±

2

Time: 1000

±

12 Hours

1. Operating Temperature Range: -55

TO +125

2.

Storage Condition: The temperature should be within -40

~85

and humidity should be less than 75% RH.

The product should be used within 6 months from the time of delivery.