(4) RELIABILITY TEST METHOD

MECHANICAL

TEST ITEM

SPECIFICATION

TEST DETAILS

Humidity

Impedance:Within

±20% of the initial value.

After the samples shall be soldered onto the test circuit

resistance

Insulation resistance and DC resistance on the

board,the test shall be done.

specification(refer to clause 2-1) shall be met.

Measurement : After placing for 24 hours min.

The terminal electrode and the ferrite must not

Temperature : +60

±2℃ , Humidity : 90 to 95 %RH

damaged.

Applied voltage : Rated voltage

Applied current : Rated current

Testing time : 500

±12 hours

Thermal shock

Impedance:Within

±20% of the initial value.

Insulation resistance and DC resistance on the

specification(refer to clause 2-1) shall be met.

The terminal electrode and the ferrite must

not damaged.

Low

Impedance:Within

±20% of the initial value.

After the samples shall be soldered onto the test

temperature

Insulation resistance and DC resistance on the

circuit board,the test shall be done.

storage

specification(refer to clause 2-1) shall be met.

Measurement : After placing for 24 hours min.

The terminal electrode and the ferrite must

Temperature : -40

±2℃

not damaged.

Testing time : 500

±12 hours

Vibration

Impedance:Within

±20% of the initial value.

After the samples shall be soldered onto the test circuit

Insulation resistance and DC resistance on

board,the test shall be done.

the specification(refer to clause 2-1)

Frequency : 10 to 55 Hz

shall be met.

Amplitude : 1.52 mm

The terminal electrode and the ferrite must

Dimension and times : X ,Y and Z directions

not damaged.

for 2 hours each.

Solderability

New solder More than 75%

Flux (rosin, isopropyl alcohol{JIS-K-1522}) shall be coated

over the whole of the sample before hard, the sample shall

then be preheated for about 2 minutes in a temperature

of 130~150℃ and after it has been immersed to a depth

0.5mm below for 3

±0.2 seconds fully in molten solder

M705 with a temperature of 245

±5℃. More than 75% of the

electrode sections shall be couered

with new solder smoothly when the sample is taken out

of the solder bath.