Item

Specifications

Test conditions

Low

There must be no case deformation

Inductors shall be subjected to temperature

temperature

or change in dimensions.

-40

±2℃ for 48±12 hours.

storage

Inductance must not change more

Measure the test items after leaving the

than the stated tolerance.

inductors at room temperature and humidity

for 1 to 2 hours.

Resistance to

There must be no case deformation,

Inductors must withstand 6 minutes of

solvent

change in dimensions, or

alcohol or water.

obliteration of marking.

Thermal

There must be no case deformation

Inductors shall be subjected to 10 cycles

shock

or change in dimensions.

to the the following temperature cycle:

Inductance must not change more

than the stated tolerance.

Measure the test items after leaving the

inductors at room temperature and humidity

for 2 hours.

MHSC-2012C-SERIES

Page-4/7

M A G .LAY ER S

-40℃

+125℃

30 min.

30 min.

1 cycle

30 sec