Table, Mag.layers, Rdc test point – Mag Layers USA MSI-600608 User Manual

Page 2

Advertising
background image

TABLE

Inductance

Percent

L Test

Resistance

Rated DC Current

L(μH)

Tolerance

Frequency

RDC(mΩ)

IDC1(A)

IDC2(A)

0.10

M,N

100kHz/1.0V

0.23±7%

40

35

R10

XXXX

0.20

M,N

100kHz/1.0V

0.23±7%

22

35

R20

XXXX

specify the inductance tolerance,M(±20%),N(±30%)

IDC1 Based on inductance change (L/Lo drop 20% Typ.)@ ambient temp. 25(For R10-E)

IDC1 Based on inductance change (L/Lo 0.1uH Min.)@ ambient temp. 25

IDC2 Based on temperature rise (T 40 TYP.)

Rated DC Current The less value which is IDC1 or IDC2 .

The nominal DCR is measured from point ato pointb.

Page-2/8

MSI-600608-SERIES-□

RDC TEST POINT

Marking

MAGLAYERS

PT/NO.

MSI-600608-R10-E

MSI-600608-R20-E

MAG.LAYERS

a

b

Advertising