TABLE

Inductance

Percent

Test

Resistance

Rated DC Current

L(μH)

Tolerance

Frequency

RDC(mΩ)

IDC1(A)

IDC2(A)

0.18

L,M

100kHz/0.1V

0.48 ±6.5%

55

36

R18

0.23

L,M

100kHz/0.1V

0.48 ±6.5%

47

36

R23

0.36

L,M

100kHz/0.1V

0.48 ±6.5%

30

36

R36

specify the inductance tolerance,L(±15%),M(±20%)

IDC1 Based on inductance change (L/Lodrop 20% Typ.)@ ambient temp. 25

IDC2 Based on temperature rise (T 40 TYP.)

Rated DC Current The less value which is IDC1 or IDC2 .

The nominal DCR is measured from point ato pointb.

Page-2/8

RDC TEST POINT

MSI-121006-SERIES

Marking

MAGLAYERS

PT/NO.

MSI-121006-R18

MSI-121006-R23

MSI-121006-R36

MAG.LAYERS