TABLE 1

Inductance

Percent

Test

Resistance Rated DC Current

L(

μH)

Tolerance

Frequency

RDC(

Ω) Max. IDC1(A) IDC2(A)

2.2

N

100kHz/0.25V

41m

0.85

2.30

2R2

3.3

N

100kHz/0.25V

54m

0.75

2.10

3R3

4.7

N

100kHz/0.25V

78m

0.63

1.65

4R7

MSCDRI-2D18LD-6R8□

6.8

N

100kHz/0.25V

0.106

0.52

1.32

6R8

MSCDRI-2D18LD-100□

10

M,N

100kHz/0.25V

0.18

0.43

1.00

100

MSCDRI-2D18LD-150□

15

N

100kHz/0.25V

0.22

0.35

0.80

150

22

M,N

100kHz/0.25V

0.32

0.30

0.68

220

33

M,N

100kHz/0.25V

0.46

0.24

0.56

330

47

M,N

100kHz/0.25V

0.66

0.20

0.48

470

※ □ specify the inductance tolerance,M(

±20%),N(±30%)

※ IDC1: Based on inductance change (△L/Lo:drop 35% Max.) @ ambient temp. 25℃

IDC2: Based on temperature rise (△T: 40℃ TYP.)

Rated DC Current: The less value which is IDC1 or IDC2.