NOTE

Dimensions in mm

PRODUCT NO.

A

B

C

D

E

MMD-10CZ-SERIES-X2

11.5 Max

10 ± 0.3

3.0 Max

3.0 ± 0.5

2.0 ± 0.5

E

E

E

L

L

L

E

E

E

C

C

C

T

T

T

R

R

R

I

I

I

C

C

C

A

A

A

L

L

L

R

R

R

E

E

E

Q

Q

Q

U

U

U

I

I

I

R

R

R

E

E

E

M

M

M

E

E

E

N

N

N

T

T

T

S

S

S

R

dc

(m

Ω

)

PART NUMBER

INDUCTANCE

Lo(

μ

H)

±

20%

@0A

Typ.

Max

HEAT RATING

CURRENT(Idc)

DC AMPS

1

SATURATION

CURRENT(Isat)

DC AMPS

2

MMD-10CZ-R12M-X2

0.12

0.65

0.75

30

75

MMD-10CZ-R36M-X2

0.36

1.3

1.6

23

28

MMD-10CZ-R47M-X2

0.47

2.1

2.5

20

26

MMD-10CZ-R56M-X2

0.56

2.4

3.0

16

24

MMD-10CZ-1R0M-X2

1.0

5.3

6.0

13

18

MMD-10CZ-1R5M-X2

1.5

6.5

7.5

10

20

MMD-10CZ-2R2M-X2

2.2

8.0

9.0

13

16

MMD-10CZ-3R3M-X2

3.3

14.5

16

9.0

14

MMD-10CZ-4R7M-X2

4.7

20.5

22.5

7.0

13

MMD-10CZ-8R2M-X2

8.2

35

45

5.0

8.5

MMD-10CZ-100M-X2

10

50

55

5.0

7.5

TEST FREQUENCY:100KHz,0.25V

TESTING INSTRUMENT L : Agilent4284A,WK4235,CH3302/G LCR METER

CH1320,CH1320S BIAS CURRENT SOURCE

R

dc

:CH11025,GOM802 MICRO OHMMETER

NOTES:
1.DC current (I

dc

) that will cause an approximate

T of 40

2.DC current (I

sat

) that will cause Lo to drop approximately 30%

3.All test data is referenced to 25

ambient

4.Operating Temperature Range -55

to +125

5.The part temperature (ambient + temp rise) should not exceed 125

under worst case operating conditions. Circuit design, component placement,

PWB trace size and thickness, airflow and other cooling provisions all affect

the part temperature. Part temperature should be verified in the end application.

Advertising