Problem

Possible Cause

Remedy

Unit not cold enough.

• Control set too warm.

• Airflow to front grille blocked.

• Excessive usage or prolonged door

openings.

• Door gasket not sealing properly.

• Adjust temperature colder. See page

7 for adjusting thermostat. Allow 24

hours for temperature to stabilize.

• Airflow must not be obstructed to

front grille. See “clearances” on page

4.

• Allow temperature to stabilize for at

least 24 hours.

• Check door alignment and/or adjust

or replace door gasket.

Unit too cold.

• Control set too cold.

• Adjust temperature warmer. See page

7 for adjusting thermostat. Allow 24

hours for temperature to stabilize.

Noise or Vibration.

• Unit not level.

• Level unit, see “Leveling Legs” on

page 4.

Unit will not run.

• No power to unit.

• Circuit breaker tripped, reset circuit

breaker.

TROUBLESHOOTING YOUR REFRIGERATOR

9

Before You Call for Service

If the unit appears to be malfunctioning, read through this

manual first. If the problem persists, check the troubleshooting

guide below. Locate the problem in the guide and refer to the

cause and its remedy before calling for service. The problem may

be something very simple that can be solved without a service

call. However, it may be required to contact your dealer or a

qualified service technician.

Electrocution Hazard - Never attempt to repair or perform main-

tenance on the unit until the main electrical power has been

disconnected. Turning the unit control “OFF” does not remove

electrical power from the units wiring.

Advertising
This manual is related to the following products: