THIS PROCESS. Once the new firmware has been
successfully burned into the StarLock a message
indicating the operation is complete will be posted on
the bottom of the display.
NOTE: Close the StarLock Utility program and cycle
the telescope power off and then on again to complete
the update.
Monitoring StarLock Guiding
There are two different methods of monitoring StarLock
guide performance. The first method is to look at the
guiding history as a “Point Spread Function”. This
presentation basically sums up the images of the
guide star at each guide update cycle. It provides a
good prediction of how well tracking is going and on
the seeing conditions. To use this method, click on the
PSF button.
The field of view of the display is approximately 20

arcseconds across. If your star is stretched horizontally,
you are either not tracking aggressively enough, or you
are tracking too aggressively. Change the Guide Rate
setting under the StarLock menu on the telescope,
reset the PSF and start a new measurement, if your
star gets worse, change the Guide Rate in the other
direction. Adjust your rate for best results with your
seeing conditions.

51

Appendix B

centered as possible as you switch between the wide
field and narrow field images.
Additional controls that will be helpful are the
“Exposure” control and the “Contrast” control. For most
nighttime viewing the contrast control should be set
about 2/3rds toward the right. For daylight viewing the
contrast should be all the way to the left. This control
allows you to look at only a subrange of and image.
It is primarily for testing the StarLock using nighttime
stars that may be very faint.
When viewing StarLock images, the location and
intensity of brightest feature in the image are displayed
below the image and updated each time the image
is refreshed. It is important to adjust your exposure
downward if your peak values are hitting 255.
Updating
The Utility program also has the ability to load new
firmware into the StarLock. The firmware release code
must first be downloaded from Meade’s website. It
should be put in an easily located directory such as your
desktop. The file will be named “StarLock_Vxy.Ldr”.
To update the firmware, establish a serial connection
with the StarLock by getting images to download by
pressing the FOCUS button. Once you have a good
connection, click the button again to stop focusing and
then click the “Update” button. A file dialog similar to
the one below will appear:
Navigate to the new firmware version and either
double click on it, or select it and click on “Open.” The
status bar at the bottom of the screen will show you the
firmware being download. After the firmware has been
successfully downloaded and checked for correctness,
it will be burned into the StarLock. DO NOT POWER
OFF THE COMPUTER OR TELESCOPE DURING

Fig 40: Update file dialog screen

Fig 41: Monitoring StarLock — PSF button