ATX DC-DC Converter Series

Input Requirements: 12-25V un-regulated, min=2A, max=10A (load
dependent).

Max Input Voltage supported by TVS clamp=26.5V. NOTE: Above
26.5V, the TVS protection diode will clamp and burn the input fuse.

Size: 44.5mm(L) * 20mm(W) * 30mm (H) (1U compliant)

Weight: 70gramms, including cable harness, 35 grams without cable
harness.

DC-Jack: Female, panel mount, 2.5*5.5*10 mm.

Connectors
Molex 39-01-2200, two 3.5” drive power connector, 1 floppy.

Overload protection
Over load protection will be effected when either of the loads (+5V &
+3.3V) exceeds 140% Max Load.

Turn-on Delay
After turning on, at least 10 ms will be needed for the rise of +5VSB
output voltage (measured from 10% to 95%) to reach its peak.

Remote ON/OFF control
Logic level is LOW - Output voltage is enabled (PS_ON pin)
Logic level is HIGH - Output voltage is disabled (PS_ON pin)

Operating environment: Temperature: -40 to 65 degree centigrade.
NOTE: Unit temperature can reach up to 85C on the surface.

Relative Humidity: 10 to 90 percent, non-condensing.

Efficiency, MTBF: 95%. MTBF=100K hours at 55Celsius.

Shipping and storage: Temperature -40 to +90 degree centigrade.
Relative humidity 5 to 95 percent, non-condensing

Warranty
1 Year Limited Warranty statement. Warranty is void if maintenance or
calibration is performed by end-user or by use in conjunction with
power modules not provided by mini-box.com.