If using a portable generator, ensure the generator meets the following minimum requirements:

5 KW

120/240 volts

41.7/20.8 amps

Single Phase

This saw is to be used with a Ground Fault Circuit Interrupter.

When loosing the Cutting Head Adjusting Knob, the Cutting Head will pivot

down unless held.

(A)

Ensure the ON/OFF Switch

is in the OFF position

(B)

Plug MK-101 into the GFCI

(C)

Plug the GFCI into the

Power source *

VOlTaGe

120V

CYCle

60hz

PHaSe

1-phase

CAUTION

4. If using an extension power cord, made sure, the length and wire gauge

correspond to the requirements listed in the table on page 10. An extension

power cord that is too small in wire gauge (diameter), or too long in length, will

cause the motor to overheat and could cause premature failure.

NOTe: In order to avoid breaker tripping, a 20-amp circuit breaker should be used.

PORTaBle GeNeRaTOR

GROUND FaUlT CiRCUiT iNTeRRUPTeR (GFCi)

SeT CUTTiNG DePTH

5. Use an approved Ground Fault Circuit Interrupter (GFCI)

6. Do not cover the motor vents as this could lead to motor overheating.

(A)

Loosen Cutting Head Knob and

move cutting head down

(B)

Set cutting depth approximately

1/4 to 1/2 inch below the surface

of the Movable Cutting Table

(C)

Ensure the Adjusting Knob is

tight