MK Diamond MK-212 User Manual

Page 32

Advertising
background image

32

MK-212 SAW

MAINTENANCE

COOLING FLOW

(B)

Remove the Cooling Transfer

Tube from the Blade Guard inlet.

(A)

Verify the cooling flow Adjusting

Clamp is open.

(C)

Place Pump into a bucket of water

and check flow.

(E)

Remove the Pump Discharge

Fitting and check for flow.

(D)

Remove the Cooling Transfer

Tube and check for flow.

(F)

Remove the Pump Intake Screen

and check for debris – clean the

screen if necessary.

NOTE: “Rodding” cooling channels is performed by inserting a small wire rod through the cooling

inlet on top of the Blade Guard and directing the rod out through each of the cooling flow tubes lo-

cated on the underside of the Blade Guard. The cooling channels should be “rodded” until all ports

are free of foreign debris.

(G)

Rod (clean out) the Cooling

Manifold and then recheck flow.

Advertising