Mk-sdg safety – MK Diamond MK-SDG User Manual

Page 10

Advertising
background image

10

Use of under sized extension cords result in low voltage to the motor that can

result in motor burnout and premature failure. MK Diamond warns that equipment

returned to us showing signs of being run in a low voltage condition, through the use

of undersized extension cords will be repaired or replaced totally at the customer's

expense. There will be no warranty claim.

To choose the proper extension cord,

• Locate the length of extension cord needed in the table below.

• Once the proper length is found, move down the column to obtain the correct

AWG size required for that length of extension cord.

To reduce the risk of electrocution, keep all connections dry and off the ground. Do

not touch the plug with wet hands.

WARNING

WARNING

EXTENSION CORD MINIMUM GAGE FOR LENGTH

VOLTS

TOTAL LENGTH OF CORD IN FEET

25 ft. AWG

50 ft. AWG

100 ft. AWG

150 ft. AWG

115v

14

12

Not Recommended

Not Recommended

230v

N/A

14

12

N/A

MK-SDG SAFETY