Battery connection, Wiring and battery information – MotorGuide X3-40 User Manual

Page 15

Advertising
background image

WIRING AND BATTERY INFORMATION

eng

11

Battery Connection

!

CAUTION

Disconnecting or connecting the battery cables in the incorrect order can cause

injury from electrical shock or can damage the electrical system. Always disconnect

the negative (‑) battery cable first and connect it last.

12-VOLT BATTERY CONNECTION

1. Install a 50‑amp (good) or 60‑amp (best) manual reset circuit breaker in line

with the trolling motor power cable positive (+) lead and the battery positive (+)

terminal. Connect the trolling motor positive lead to the trolling motor battery

positive (+) terminal.

2. Connect the black trolling motor power cable negative (–) lead to the trolling

motor battery negative (–) terminal.

3. Connect a common ground bond from the trolling motor battery negative (–)

terminal to the engine starting battery negative (–) terminal.

a -

Power cables to trolling

motor

b -

Manual reset circuit

breaker

c -

Trolling motor battery

d -

Engine starting battery

e -

Power cables to engine

f -

Common ground bond

24-VOLT BATTERY CONNECTION

1. Install a 50‑amp (good) or 60‑amp (best) manual reset circuit breaker in line

with the trolling motor power cable positive (+) lead and the trolling motor

battery B positive (+) terminal.

2. Connect the positive (+) trolling motor lead to the positive (+) terminal on trolling

motor battery B.

3. Connect a jumper wire (reference gray) between the negative (–) terminal on

battery B to the positive (+) terminal on battery A.

IMPORTANT: The jumper wire should be the same wire gauge as the negative (–)

and positive (+) power cables.

4. Connect the trolling motor negative (–) lead to the negative (–) terminal on

battery A.

RED

BLK

BLK

REDRED

a

b

c

e

f

d