Reducing the fluid temperature, Reducing the fluid temperature 20, A low fluid level. see – MTS Model 512-01 Hydraulic Power Unit User Manual

Page 20: Reducing the fluid, Temperature

Advertising
background image

Model 512.01 Hydraulic Power Unit

20

Maintenance

Reducing the Fluid Temperature

The hydraulic power unit (HPU) will be shut down if the hydraulic fluid
reaches a temperature of 55°C (130° F).

1.

Check the thermometer. The HPU shuts down when fluid gets hotter
than about 55ºC (130ºF).

2.

Press the Start button. Hold it down to override the overtemperature
sensor.

If overtemperature fluid caused the shutdown, the HPU will now
start to run.

Keep holding the Start button until the HPU stays running when
you let go of this button. This could take several minutes.

If the HPU still does not run, something else caused the shutdown.

3.

Once the HPU is running, put the HPU in a no-flow condition (where
no fluid is flowing to other hydraulic equipment).

4.

Let the HPU run. Wait 15 minutes for its temperature to stabilize.
Check the fluid temperature.

If the temperature is between 43 and 52ºC (109 and 126ºF), stop.