If zero algorithm=4 – MTS SWIFT 20 Ultra Sensor User Manual

Page 87

Advertising
background image

Test Track Vehicle for Slip Ring Sensor

SWIFT 20 Sensors

Installing the Transducer

87

This zero method samples all eight input bridges on every encoder tick, for one
complete revolution. After the data is taken, all eight input channels are analyzed
for signal offsets, and the X and Z input channels are analyzed to determine the
angular zero point.

Example of a .cal file

If Zero Algorithm=4

When you zero the TI, you want the vehicle to be fairly level and the transducer
to be as close to plumb as practical.

1. Install the SWIFT sensor(s) and data collection equipment on the vehicle.

2. Connect all cables and turn on the power to the TI boxes.

3. Let the TI boxes and transducers warm up for 15-20 minutes.

4. Run the TISTATUS program to compare the supply voltages to the

reference voltages.

Type:

TIstatus <port#> <box#>

If the supply voltages vary more than 0.5 V from the reference voltages,
there is a power supply problem that must be resolved before you can
continue.

5. Verify that the calibration file is set up correctly for your testing application.

[SWIFT]

Name=zero 3 after new tire

SerialNum=1234567

Normalization=0

InputSwitches=255

OutputPolarities=40

ZeroAlgorithm=4

AngleMode=0

AngleOffset=82.0898

AngleFixed=0

EncoderSize=1

ZFX1=0.103786

ZFX2=-0.023199

ZFY1=-0.094017

ZFY2=-0.184371

ZFY3=-0.225885

ZFY4=-0.269841

ZFZ1=-0.101343

ZFZ2=-0.045177

KFX1=0.196337

KFX2=0.195604

KFY1=0.169231

KFY2=0.166789

KFY3=0.167277

KFY4=0.16801

KFZ1=0.195849

KFZ2=0.196581

KMX=3.7558

KMYX=2.39805

KMYZ=2.5641

KMZ=3.75824

KFXFY=0.000611

KFXFZ=-0.00315

KFXMX=0.008864

KFXMY=-0.005348

KFXMZ= 0017998

S20-38

Zero Algorithm

0

Non-spinning mode

1

Spinning mode (uses a digital

inclinometer for angle zero and

spinning the tire for the bridge zero

process

2

Not used

3

Spinning mode (uses spinning the

tire for both angle and bridge

processes)

4

Spinning mode (use a digital

inclinometer to define two positions

90° apart for the bridge zero and

angle zero processes.

Angle Mode

0

Spinning mode (obtains angle from

the encoder)

1

Fixed angle mode (used for test rigs

in the lab)

Advertising