Motor – BEA Horton C2150 User Manual

Page 18

Advertising
background image

SIZE:

DRAWN BY:

B

100 ENTERPRISE DRIVE

PITTSBURGH, PA 15275
PHONE: (412) 249-4100
FAX: (412) 249-4101
EMAIL: www.beasensors.com

REV BY:

TUC

TUC

80.0208.01

SCALE:

DATE:

NONE

19 OCT 2005

PART NO:

SHEET
1 OF 1

IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC. FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME
AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS, CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT LEAVE
ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER
SACRIFICE THE SAFE OPERATION OF THE AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM

NOTES: 1) CAP OFF REMAINING UNUSED WIRES ON LO21.

2) LO21 DIP SWITCHES 1-5 FOR LOCKOUT TIME., #6,7,8, NOT USED.
3) OPTION: CONNECT LO21 MOTOR LEAD RED TO TERMINAL 1 AND BLACK TO TERMINAL 12.

1

2

3

4

5

6

7

8

9

10

11

12

ACTUATION

COMMON

+ 24 VDC

COMMON

COMMON

SAFETY

TOGGLE

+ 24 VDC

STOPNR'SUM

STOP-N-SEEK

UNLOCK

OPEN

C4190 CONTROL

CN3

24 VAC

F2

F3

F1

BREAKOUT SWITCH

AUTOMATIC

OFF

HOLD OPEN

C4320-1 ROCKER SWITCH

C3938 P/S

MOTOR

-

+

TITLE: HORTON C4190 CONTROL WITH

PARALLAX 2 SYSTEM, LO21
Q-DISCONNECT ON APPROACH SIDE

Advertising