Bodyguard, 24 v transformer, Lo21b/u – BEA Horton C2150 User Manual

Page 10

Advertising
background image

SIZE:

DRAWN BY:

B

100 ENTERPRISE DRIVE
PITTSBURGH, PA 15275
PHONE: (412) 249-4100
FAX: (412) 249-4101
EMAIL: www.beasensors.com

REV BY:

KJG

TUC

SCALE:

DATE:

NONE

11/01/07

PART NO:

SHEET

1 OF 1

TITLE: HORTON 4160-1, 2 CONTROL with

LO-21, LO21U, BODYGUARD

80.0100.03

BR

O

W

N

OR

ANGE

VIOLET

RED

BL

A

C

K

GRE

E

N

Y

E

LLO

W

BLUE

DATA + 7
blue
DATA - 6
brown
N.C. 5

N.O. 4
green
COM 3
white
POWER 2
black
POWER 1
red

BODYGUARD

GRAY

WHITE

RED/ WHITE

24 V

TRANSFORMER

BLACK/ W

H

IT

E

HORTON 4160-1,2

DOOR

CONTROL

ACTIVATE

(BLACK)

COMMON

(WHITE)

SAFETY

(GREEN)

OPERATOR

MOTOR

MOTOR VOLTAGE

+

-

NOTES: 1 ) BEA RECOMMENDS USING THE LO-21

2 ) LO-21 RED AND BLACK WIRES MUST CONNECT TO THE CORRECT MOTOR POLARITY, RED=POSITIVE, BLACK=NEGATIVE.
3 ) WHEN USING DC VOLTAGE, POLARITY MUST BE MAINTAINED AS ORANGE: (-) BROWN: (+)
4 ) NOTE REF LO21: CONNECT THE DASHED LINES

GREEN,BLUE,BLACK/WHITE,PURPLE, & GRAY IF SBK BEAMS ARE USED. IF DRY CONTACT BEAMS (MICROCELL BEAMS)
ARE USED CONNECT MICROCELL COM. & N.O. TO PURPLE & GRAY RESPECTIVLEY, THEN BLUE & GREEN TO DOOR CONTROL COM. & SAFETY RESPECTIVLEY.

RED

GREEN

OFF

ON

LO21 DEFAULT DIP SWITCHES

BRO

W

N

ORANG

E

BLUE

RED

BL

ACK

EM

IT

T

E

R

RE

CEIVE

R

+ -

+

-

BROWN

GREEN

WHITE

WHITE

BROWN

24 V

TRANSFORMER

BLACK/ W

H

IT

E

PURP

L

E

GRAY

DATA + 7
blue
DATA - 6
brown
N.C. 5

N.O. 4
green
COM 3
white
POWER 2
black
POWER 1
red

BODYGUARD

GREEN

RED/ WHITE

WHITE

HORTON 4160-1,2

DOOR

CONTROL

OPERATOR

MOTOR

MOTOR VOLTAGE

+

-

ACTIVATE

(BLACK)

COMMON

(WHITE)

SAFETY

(GREEN)

IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC. FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME
AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS, CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT LEAVE
ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER
SACRIFICE THE SAFE OPERATION OF THE AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM

RED

GREEN

OFF

ON

LO21B/U

RA WH 1

RA BL 2

EA WH 3

EA BL 4

5 NC
4 NO
3 COM
2 12-24 VAC/DC
1 12-24 VAC/DC

RB WH 1

RB BL 2

EB WH 3

EB BL 4

* RECEIVER (A), EMITTER (A)

RECEIVER (B), EMITTER(B)
WH= WHITE, BL= BLACK

MICROCELL ONE

ON

1 2 3 4