252 servovalve general specifications, 252 servovalve general specifications 20 – MTS Series 252 Servovalves User Manual

Page 20

Advertising
background image

Series 252 Servovalve Product Information

20

252 Servovalve General Specifications

Introduction

252 Servovalve General Specifications

Parameter

Specification

Maximum operating pressure

31 MPa (4500 psi)

*

* Higher operating pressures, up to 35 MPa (5000 psi), are available on

request. Contact MTS for further information.

Minimum operating pressure

1.4 MPa (200 psi)

Operating temperature range

Revision G only

-40°C to +135°C (-40°F to +275°F)

-20°C to +135°C (-40°F to +275°F)

Rated full-flow input signal current

25 mA (series)
50 mA (differential)
50 mA total (parallel)

Coil resistance

80

Ω

per coil

Seals

Viton

Weight

252.2X/.4X Revision C
252.2X/.4X Revision G
252.3X

1.03 kg (2.3 lb)
0.97 kg (2.1 lb)
3.5 kg (7.5 lb)

Hydraulic Fluid

† Do not mix different types or brands of hydraulic fluid. Mixing different

hydraulic fluids can create contaminants and degrade fluid additives. For
information on hydraulic fluid, contact MTS Systems Corporation.

Mobil DTE 25 or Shell Tellus 46