252 servovalve general specifications, 252 servovalve general specifications 20 – MTS Series 252 Servovalves User Manual
Page 20
Series 252 Servovalve Product Information
20
252 Servovalve General Specifications
Introduction
252 Servovalve General Specifications
Parameter
Specification
Maximum operating pressure
31 MPa (4500 psi)
*
* Higher operating pressures, up to 35 MPa (5000 psi), are available on
request. Contact MTS for further information.
Minimum operating pressure
1.4 MPa (200 psi)
Operating temperature range
Revision G only
-40°C to +135°C (-40°F to +275°F)
-20°C to +135°C (-40°F to +275°F)
Rated full-flow input signal current
25 mA (series)
50 mA (differential)
50 mA total (parallel)
Coil resistance
80
Ω
per coil
Seals
Viton
Weight
252.2X/.4X Revision C
252.2X/.4X Revision G
252.3X
1.03 kg (2.3 lb)
0.97 kg (2.1 lb)
3.5 kg (7.5 lb)
Hydraulic Fluid
†
† Do not mix different types or brands of hydraulic fluid. Mixing different
hydraulic fluids can create contaminants and degrade fluid additives. For
information on hydraulic fluid, contact MTS Systems Corporation.
Mobil DTE 25 or Shell Tellus 46