IT IS RECOMMENDED THAT THE TO15000 BE INSTALLED BY A LICENSED, PROFESSIONAL PLUMBER.

ALSO, FOR EASE OF INSTALLATION, IT IS RECOMMENDED THAT THE TO15000 SYSTEM BE INSTALLED

WITH AN OPTIONAL BYPASS VALVE KIT

Installation Guidelines

The following are guidelines for installing the TO15000 to the main water supply line for the whole house
WITHOUT the use of the optional bypass valve kit.

A. Prepare the TO15000 housing lid for installation:

1.

Open the housing, using the handtool if necessary.

2.

Remove the housing bottom and filter from the lid.

3.

Attach the bracket to the housing lid.

4.

Mount the bracket (with lid attached) to a wall or post as close to the houe plumbing
as possible.

NOTE: Allow at least a 4" clearance at the bottom for changing the filters.

B. Prepare the House Plumbing for installation (parts supplied by

plumber):

1. Locate the main water supply line that supplies all water going into the house.
2. Shut off water to the house. Close all faucets in the house to avoid back flow of the

water.

3. Disconnect or sever the water line (if a pressure regulator is installed, make the

connection after the regulator - between the regulator and the house).

4.

Install the necessary plumbing to enable you to connect the water supply line to the
TO15000 unit.

5.

Connect the inflowing water line to the IN (inlet) port of the TO15000 unit.

6.

Then connect the OUT (outlet) port on the TO15000 housing lid to the outflowing
water pipe, the pipe going into the house.

C. Installation of the Housing Bottom and Filter:

1.

Check the filter cartridge to:
a. Confirm that the white rubber washer is in the groove around the filter nipple

(top of filter) and that the two black orings are in place on the nipple.

b. Confirm that the white rubber washer is in the groove in the center of the

bottom cap on the filter.

2.

Insert the filter nipple in the center port inside the housing top. When the filter is
fully inserted, it should stay in place.

3.

Check the large oring around the mouth of the housing bottom to confirm that it is in place.

4.

Reconnect the housing top and bottom by sliding the bottom up and over the filter. Turn the
housing bottom until it is tightly sealed.

IN

OUT

orings

washer

large oring

red button