operation

8. If the engine has started, and the choke lever was

moved to the

CloSeD position to start the engine,

gradually move the choke lever to the

open position

(Figure 9) as the engine warms up. If the engine has

not started repeat steps 1 through 6.

9. Before the water trailer is placed into operation, run

the engine for several minutes.

10. Check for fuel leaks and noises that would be

associated with a loose component. Check for leaks

between pump and engine. If water is leaking between

the pump and engine housing, the seal inside the

pump may be worn or damaged. Continued operation

of the pump is not recommended. Further usage of the

pump under these conditions may cause severe water

damage to engine.

11. To begin pumping, place the throttle lever (Figure 12)

in the

run position.

Figure 12. Throttle Lever (Run)

.

12. Set manifold and spray bar control handles as

referenced in Table 5 to activate pumping.

Stopping The Engine

Normal Shutdown

1. Move the throttle lever to the

IDLE position (Figure

13) and run the engine for three minutes at low speed.

Figure 13. Throttle Lever (Idle)

2. After the engine cools, turn the engine ON/OFF switch

to the

oFF position (Figure 14).

Figure 14. Engine ON/OFF Switch (OFF Position)

3. Place the fuel shut-off lever (Figure 15) in the

oFF

position.

Figure 15. Fuel Valve Lever (OFF)

Emergency Showdown

1. Move the throttle lever quickly to the

IDLE position, and

place the engine ON/OFF switch in the

oFF position.