Stow porto mixer— maintenance, Caution – Multiquip SMC3PB User Manual

Page 25

Advertising
background image

STOW PORTO MIXER — PARTS & OPERATION MANUAL — REV. #0 (08/08/03) — PAGE 25

STOW PORTO MIXER— MAINTENANCE

Maintenance

Gearbox Oil Check

1. Position the mixer on a level surface and place a

support

block

under the front of the mixer frame as shown in Figure 29. This
will level the mixer.

2.

NEVER!

check the gearbox oil level with the mixer tilted up or

down.

ALWAYS

check the gearbox oil level with the mixer in a

level position.

Figure 29. Mixer Positioning (Gearbox Oil Level)

5. Insert oil filler plug and tighten.

Figure 30. Gearbox Oil Level Check

Gerarbox Removal

1. Remove drum by turning counter-clockwise to release from

gearbox shaft.

2. Remove pulley, remember the nut securing the pulley is

left-hand threaded. Remove circlip, and draw out shaft.

3. Remove the 5 bolts securing rear plate.

4. Reassemble in reverse order, taking care to ensure gear teeth

are meshed correctly.

V-Belt Check

1. To adjust V-belts, remove V-belt cover and loosen the main

motor mount bolts (Figure 31), raise electric motor and
retighten bolts. Belt tension should be adjusted so that the
maximum deflection is approximately 3/8 inch (10 mm).

2. Replace V-belt cover.

CAUTION :

Check the gearbox oil level

monthly before

operating mixer. Low oil level or no oil will
severely damage gearbox.

3. Before inspecting the gearbox oil level, make sure the gearbox

is cold before removing the filler plug. Hot! oil can burn skin and
cause injury. Let oil

cool

before checking.

4. Remove gearbox oil filler plug (Figure 30) and fill with EP90 or

similar gear oil to the level of the filler plug. Replace gearbox oil
every 3,000 hours. Gerabox oil capacity is

8-10 ounces

.

Figure 31. V-belt Adjustment

Advertising
This manual is related to the following products: