Maintenance

Installing pans Onto Finisher Blades

These round discs sometimes referred to as "pans" attach

to the spiders arms and allow early floating on wet concrete

and easy movement from wet to dry areas. They are also

very effective in embedding large aggregates and surface

hardeners.

1. Lift trowel just enough to slide pan under blades. Lower

finisher onto pan with blades assembly adjacent to

Z-Clips.

2. Rotate blades into position under Z-Clips (Figure 45).

Ensure that the blades are rotated in the direction of

travel when the machine is in operation or use the

engine to rotate the blades into position.

Figure 45. Z-Clip Finisher Pan Installation

WaRNINg

Lifting/Crush Hazard.

DO NOT lift trowel

with pans attached.

WaRNINg

aLWayS install pans either on the work area or on an

area that is next to and level with the work area.

DO

NOT lift the trowel when the pans are attached.

Blade Assembly

Tie-Down Knob

Tie-Down,
Blade

Z-Clip, Pan

3. Attach the blade tie-downs to the far side of the Z-Clip

brackets with tie-down knobs as shown in Figure 45.

4. Check to make certain that the blade edges are

secured under the Z-Clips and the tie-downs are

secured completely over the edges of the blade bar

before the machine is put back into operation.

Checking Hydraulic Steering pressure

Many hydraulic problems are a result of low fluid levels.

Before checking any other possibilities, make sure the

hydraulic fluid level is up to the top of the sight glass which

is located at the back/center of the frame.
Hydrostatic pressure can be checked using a pressure

gauge with a range of at least 5,000 psi. Two male

diagnostic quick couplers/test ports (one for each pump)

are located beneath the right grill guard (Figure 46).

Figure 46. QD Male Couplers Location

WaRNINg

NeveR use your hand to find hydraulic

leaks. Use a piece of wood or cardboard.

Hydraulic fluid injected into the skin must

be treated by a knowledgable physician

immediately or severe injury or death can

occur.

QUICK DISCONNECT

MALE COUPLERS