b46S90 WaLK-beHIND TROWeL • OpeRaTION aND paRTS maNUaL — Rev. #0 (06/13/13) — page 21

inspection/operation

centrifugal Safety "STOp" Switch

This trowel has been equipped with a centrifugal safety

"

STOP" switch (Figure 17). This switch should be tested

every time the engine is started.
The switching mechanism of this switch should operate

freely and should always be kept in this condition. With the

switch in the

Off position, the engine should not start or

run. The purpose of this switch is to stop the engine in a

runaway situation, (i.e. the operator releasing the handle

during operation).

Figure 17. Centrifugal Safety "STOP" Switch

Operation

This section is intended to assist the operator with the initial

start-up of the walk-behind trowel. It is extremely important

that this section be read carefully before attempting to use

the trowel in the field.

dO NOT use your trowel until this

section is thoroughly understood.

lifting the Trowel Onto a Slab

Extra care should be taken when lifting the trowel off the

ground. Serious damage to the machine or personal injury

could be caused by dropping a trowel.

CENTRIFUGAL

SAFETY “STOP”

SWITCH

ON

OFF

warNiNg

NeveR attempt to lift this machine alone. NeveR lift

the trowel by the guard ring as it may rotate and cause

injury.
alwayS make certain the handle is secure and use

only the manufacturer's approved lifting point. The

trowel may be lifted at the center lifting bale by crane

or other lifting device of adequate capacity.

lifting bale

The lift bale provides an optimal lift point for lifting the trowel.

When lifting the trowel onto a concrete slab, attach a chain

or rope to the lifting bale. Make sure the lifting device has

adequate lifting capacity to lift the trowel.
Using a crane or forklift (Figure 18) to lift the trowel is highly

recommended, and is perfectly safe for the trowel.

alwayS

use extra care when lifting the trowel off the ground.

Figure 18. Lifting the Trowel

NOTICE

dO NOT attempt to operate the trowel until the Safety,

General Information and Inspection sections of this

manual have been read and thoroughly understood.

NOTICE

The trowel is heavy and awkward to move around. Use

proper heavy lifting procedures and

dO NOT lift the

trowel by the guard rings.

LIFT