Troubleshooting – Multiquip Cv1A User Manual

Page 23

Advertising
background image

CV seRIes VIbRatoR motoR • opeRatIon and paRts manual — ReV. #0 (04/30/13) — page 23

troubleshooting

table 9. troubleshooting (drive motor)

symptom

possible problem

solution

Motor Does Not Start

No power to motor?

Verify unit is plugged to proper outlet. Verify

extension cords are properly plugged in and are

not cut or pinched. Verify power is available at

outlet. Check main switch or breaker.

Defective ON/OFF switch?

Replace switch.

Rattling Noise From Rear Of

Housing Area

Rear bearing failure?

Replace bearing.

Rattling Noise From Shaft End

Worn coupler?

Disconnect coupler and turn motor on. If noise

goes away, replace coupler. If noise remains,

check forward bearing.

Forward bearing failure?

Replace bearing.

table 10. troubleshooting (Flexshaft)

symptom

possible problem

solution

Flexshaft Binding

Flexshaft kinked?

Straighten out flexshaft.

Defective flexshaft?

Replace flexshaft.

Too much grease in flexshaft

casing?

Relube flexshaft.

Leaking Vibrator Head

Too much oil in head casing? Fill head casing to recommended level.
Head bearings/seals

defective?

Replace vibrator head.