Xtra-guard® 1 – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual

Page 26

Advertising
background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

54

Cable > Xtra-Guard > Xtra-Guard 1 > Multipair > Supra-Shield Foil/Braid > 300 V

Xtra-Guard® 1

High Performance

300 V Supra-Shield® Foil/Braid, Multipair

UL CM

UL AWM 2464 VW-1

CSA CMG FT4

Operating Temperature

• –30°C to +80°C (AWM)

• –30°C to +105°C (CM)

Conductor Color Coding

• 28, 26, 24, 22 AWG: Chart B

(page 516)

• 20, 18 AWG: Chart A (page 516)

• Jacket Colors

• Put-ups: slate

• Bulk: nine colors available

(page 31, minimums

may apply)

Materials

• Stranded tinned copper

conductors

• Premium PVC insulation

• Supra-Shield foil + braid shield:

Aluminum/polyester/aluminum

foil with 25% overlap min.

Tinned copper drain wire sized

the same as conductors

Tinned copper braid, 70%

coverage min.

• Nylon ripcord

• Premium PVC jacket

• UV resistant

Availability

100 ft (30.5 m)

500 ft (152 m)

1000 ft (305 m)

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-221: General-purpose,

cross-linked polyolefin (indoor)

• FIT-321: Medium-wall,

adhesive-lined, cross-linked

polyolefin (outdoor)

26 AWG (0.14 mm

2

)

Stranding: 7/34 (7 x 0.16 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Pairs

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5695

2

0.224

5.69

0.032

0.81

5696

3

0.234

5.94

0.032

0.81

5697

4

0.251

6.38

0.032

0.81

5698

5

0.270

6.86

0.032

0.81

5699

6

0.289

7.34

0.032

0.81

24 AWG (0.23 mm

2

)

Stranding: 7/32 (7 x 0.20 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Pairs

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5271C

1

0.184

4.67

0.032

0.81

5272C

2

0.240

6.10

0.032

0.81

5273C

3

0.252

6.40

0.032

0.81

5274C

4

0.271

6.88

0.032

0.81

5275C

5

0.292

7.42

0.032

0.81

5276C

6

0.314

7.98

0.032

0.81

5279C

9

0.360

9.14

0.032

0.81

5279/11C

11

0.385

9.78

0.032

0.81

5279/15C

15

0.429

10.90

0.032

0.81

5279/19C

19

0.457

11.61

0.032

0.81

5279/27C

27

0.540

13.72

0.032

0.81

5279/51C

51

0.739

18.77

0.053

1.35

28 AWG (0.09 mm

2

)

Stranding: 7/36 (7 x 0.12 mm)

Insulation Thickness: 0.010 (0.25 mm)

Part No.

Pairs

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5943

2

0.211

5.36

0.032

0.81

5944

3

0.220

5.59

0.032

0.81

5945

4

0.235

5.97

0.032

0.81

5946

5

0.252

6.40

0.032

0.81

5947

6

0.270

6.86

0.032

0.81

Advertising