Omnitron Systems Technology iConverter 4GT Plug-in Module User Manual

Iconverter, 4gt plug-in module user manual

Advertising
background image

iConverter

4GT

Plug-in Module User Manual

Product Overview
The

iConverter

4GT (PN: 8482-4) is a four-port 10/100/1000Mbps Ethernet switch that

supports Half/Full-Duplex and auto-negotiation on each RJ-45 port.
Installation Procedure
1) Configure DIP-switches
2) Install Module in Chassis and Connect Cables
3) Verify Operation

The

iConverter

4GT can be used in an unmanaged or managed configuration. When

unmanaged, it can be installed in a chassis without a Management Module. Management

of the module is accomplished by installing a Management Module (such as an

iConverter

NMM2 or GX/TM2) that provides monitoring, configuration and trap notification in the same

chassis.

1) CONFIGURE DIP-SWITCHES
DIP-SWITCH BANK 1
The location of the DIP-switches is shown in

Figure 1.
Each port can be configured for Auto Negotiation

(AN) or Manual configuration (Man). When

configured for AN, the port automatically

determines the speed, duplex and pause

capability of the connected device. If the port

is configured for Manual, the speed and duplex

is determined by the 100/10 and FDX/HDX

DIP-switches (see Figure 4 for configuration

details).
1000Mbps Manual operation is not supported. For 1000Mbps operation, configure the ports

for AN operation.
The functions of DIP-switch Bank 1 are outlined in Figure 2. DIP-switch Bank 1 switches 3 - 8

control the operation of Port 1 and Port 2. DIP-switches 1 and 2 are global settings.
SW1 and SW2: BACKPLANE ENABLE
When these DIP-switches are in the “DS” position (factory default), the Backplane Port of the

4GT is isolated from the Ethernet Backplane on the chassis. When these DIP-switches are in

the “EN” position, the Backplane Port is enabled. This allows Ethernet Backplane connectivity

to an adjacent module via the chassis A/B Backplane Link depending on the switch setting.

Refer to the chassis user manual for detailed information on the Ethernet Backplane.

at 100Mbps. If the 1000 LED is illuminated, the port is operating at 1000Mbps and if the 100

and 1000 LEDs are illuminated, the port is operating at 10Mbps.

LED Function

“Legend”

Color

OFF State

ON/Blinking State

Power

“PWR”

Green

No power

Module has power

P1 Link Activity

“100”

Green

Port not linked at 100M

ON: Port linked at 100M

Blinking: Data activity

P1 Link Activity

“1000”

Green

Port not linked at 1000M

ON: Port linked at 1000M

Blinking: Data activity

P1 Link Activity

“100” and “1000”

Green

Port not linked at 10M

ON: Port linked at 10M

Blinking: Data activity

P2 Link Activity

“100”

Green

Port not linked at 100M

ON: Port linked at 100M

Blinking: Data activity

P2 Link Activity

“1000”

Green

Port not linked at 1000M

ON: Port linked at 1000M

Blinking: Data activity

P2 Link Activity

“100” and “1000”

Green

Port not linked at 10M

ON: Port linked at 10M

Blinking: Data activity

P3 Link Activity

“100”

Green

Port not linked at 100M

ON: Port linked at 100M

Blinking: Data activity

P3 Link Activity

“1000”

Green

Port not linked at 1000M

ON: Port linked at 1000M

Blinking: Data activity

P3 Link Activity

“100” and “1000”

Green

Port not linked at 10M

ON: Port linked at 10M

Blinking: Data activity

P4 Link Activity

“100”

Green

Port not linked at 100M

ON: Port linked at 100M

Blinking: Data activity

P4 Link Activity

“1000”

Green

Port not linked at 1000M

ON: Port linked at 1000M

Blinking: Data activity

P4 Link Activity

“100” and “1000”

Green

Port not linked at 10M

ON: Port linked at 10M

Blinking: Data activity

Figure 6: LED Indicators

Software Controlled Switch Settings
Additional settings are available via software control when a 4GT is installed in an iConverter

chassis with a Management Module.
The following software only settings can be controlled via Serial Console/Telnet Console,

NetOutlook Management Software or other third-party SNMP-based clients:
– Port VLAN for UTP Ports and Backplane Ports (“A” and “B”)
– Port Access Control for UTP Ports
– MIB Statistics Reporting
– Tag VLAN for UTP Ports and Backplane Ports (“A” and “B”)
– Bandwidth Allocation for UTP Ports
Software controlled settings can be selected to override DIP-Switch settings.

040-08482-002C 8/11

Page 1

Omnitron Systems Technology * 140 Technology Dr. #500 * Irvine, CA 92618

949.250.6510 tel * 949.250.6514 fax * www.omnitron-systems.com