2

Omnitron Systems Technology, Inc.

Safety Considerations

Warning

The operating description in this Instruction Manual is for use by qualified personnel only. To
avoid electrical shock, do not perform any servicing of this unit other than that contained in the
operating instructions, unless you are qualified and certified to do so by Omnitron Systems
Technology, Inc.

Caution

All user-required operations can be performed without opening the unit. Never attempt to open
or remove the cover or tamper with the unit or tamper with the power supply module.

Warranty

This OST product is warranted to the original purchaser against defects in material and
workmanship for a period of TWO YEARS from the date of shipment. This warranty period
may be extended to LIFETIME by the original purchaser if the product is REGISTERED with
OST within 90 days from the date of shipment. TO REGISTER, PLEASE COMPLETE AND MAIL
OR FAX BACK THE REGISTRATION CARD. During the warranty period, OST will, at its option,
repair or replace a product which is proven to be defective.

For warranty service/repair, the product must be sent to an OST designated repair facility,
shipment prepaid by the Buyer. OST will pay postage/shipping charges to return the product
to Buyer (using OSTs standard shipping method).

Limitation of Warranty

The foregoing warranty shall not apply to defects resulting from improper or inadequate use
and/or maintenance of the equipment by Buyer, Buyer-supplied equipment, Buyer-supplied
interfacing, unauthorized modifications or tampering with equipment (including removal of
equipment cover by personnel not specifically authorized and certified by Omnitron), misuse,
operating outside the environmental specification of the product (including but not limited to
voltage, ambient temperature, radiation, unusual dust, etc.), or improper site preparation or
maintenance.

No other warranty is expressed or implied. Omnitron specifically disclaims the implied warran-
ties of merchantability and fitness for any particular purpose.

Exclusive Remedies

The remedies provided herein are the Buyer’s sole and exclusive remedies. Omnitron shall not
be liable for any direct, indirect, special, incidental, or consequential damages, whether based
on contract, tort, or any legal theory.

FCC Warning

This equipment has been tested and found to comply with the limits for a class A digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide a reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. The equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may cause harmful inter-
ference to radio communications. Operating this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the interference
at his own expense. Any changes or modifications not expressly approved by the manufac-
turer could void the user authority to operate the equipment.

Form:040-04100-002 9/03

Omnitron Systems Technology, Inc.

11

SPECIFICATIONS

„

Protocol:

IEEE 802.3, 10Base-T, 10Base-FL, 10Base-2

„

Interface Connectors:

Hub:

UTP: (12/24) RJ45 pins 1-2, 3-6 active

10FL Module:

Fiber: (1) ST

10B2 Module:

Coax: (1) BNC

„

Cable Types:

10Base-T UTP:

Categories 3, 4, 5 (EIA/TIA 568)

MM fiber:

50/125, 62.5/125, 100/140 um

SM fiber:

9/125 um

10Base-2 Coax:

50 ohm, RG-58A/U, RG-58C/U, RG-58/U or equivalent

„

Supported Distances:

10Base-T UTP:

100 m / 328 ft.

MM 850 nm fiber:

2 km / 1.2 mi. / 6,560 ft.

MM 1300 nm fiber:

2 km / 1.2 mi. / 6,560 ft.

SM 1300 nm fiber:

2 km / 1.2 mi. / 6,560 ft.

Coax:

185 m / 606 ft.

„

Indicators:

Hub:

Power:

LED (1), Yellow, power applied

Collision:

LED (1), Yellow, collision detected

Jabber:

LED (1), Red, jabber condition

UTP Link / Receive:

LED (12/24), Green:

device present - solid
data received - blinking

UTP Partition

LED (12/24), Red, port partitioned

10FL Module:

Fiber Link:

LED (1), Green, device detected

Fiber Receive:

LED (1), Green, data received

10B2 Module:

Coax Link:

LED (1), Green, device detected

Coax Receive:

LED (1), Green, data received

Coax Partition

LED (12/24), Red, port partitioned

„

Switches:

Hub:

UTP Crossover:

Straight / Crossed

10B2 Module:

Coax Termination:

50 Ohm In / Out

„

Dimensions / Weight:

W:19.0"xD:7.0"xH:1.75" / 7 lb.

„

Power:

110 / 230 VAC, 50 / 60 Hz

„

Environmental:

Temperature:

0 to 40 degrees C

Humidity:

0-90% (non-condensing)

TECHNICAL SUPPORT

If you encounter problems in installing this product, contact Omnitron Technical Support:

Phone:

(714) 250-6510

Fax:

(714) 250-6514

Address:

Omnitron Systems Technology, Inc.
27 Mauchly, #201
Irvine, CA 92618 USA

Email:

[email protected]

URL:

www.omnitron-systems.com