Opticon H13 User Manual

Step 3 step 2 step 1, H-13, Quick start guide

Advertising
background image

The Netherlands Opticon Sensors Europe B.V.

tel: +31 (0)23-5692700

/ email: [email protected]

U.S.A.

Opticon Inc.

tel: 800-636-0090

/ email: [email protected]

France

Opticon S.A.S.

tel: +33 (0)1-41461260

/ email: [email protected]

Germany

Opticon Sensoren GmbH

tel: +49 (0)6074-91890-0

/ email: [email protected]

Italy

Opticon s.r.l.

tel: +39 (0)051-6321800

/ email: [email protected]

Spain

Opticon Sensores S.L.

tel: +34 (0)902-747469

/ email: [email protected]

Contact

Sweden

Opticon Sensors Nordic AB

tel: +46 (0)8-58548560

/ email: [email protected]

United Kingdom Opticon Limited

tel: +44 (0)1582-635100

/ email: [email protected]

Taiwan

Opticon Far Eastern Ltd.

tel: +886 2-27597444 / email: [email protected]

China

Opticon Sensors Europe B.V., Shanghai Representative Office

tel: +86 21-64480881

/ email: [email protected]

Australia

Opticon Sensors Pty. Ltd.

tel: +61 (0)2-43402666

/ email: [email protected]

Brazil

Opticon Sensors Europe B.V., Latin American Office

tel: +55 11-5081 2088

/ email: [email protected]

Please contact OPTICON or your local dealer.

More product details, additional support, and configuration options (from the Universal Menu Book) are available at www.opticon.com.

SYSTEM MENU

1 Cancel

2 Restart

3 Download software

4 Settings

5 Show version

6 List files

7 Diagnostics

System Menu

System Menu

Battery indicator

*Please refer to the system menu instruction guide for details of default settings)

The battery charge level is shown at the lower right of the LCD screen.

Battery indicator settings can

be configured. (configured

to OFF by default.)

When the main battery charge

level becomes exceedingly

low , the battery icon starts

blinking regardless of the

battery indicator settings.

Screen Image

System menu screen starts when you press

"1", "." and the power key at the same time.

System menu screen

Battery

indicator

Remaining

battery level

Key

Function

SCAN

Scans a barcode.

Q1

Select a menu.

(These keys can be programmed for user s

application.)

Q2

SHIFT

Shifts from number input mode to alphabet

input mode and vice versa.

BS

Deletes one letter before the cursor.

CLR

Cancels an input.

POWER

Turns the power ON and OFF.

0-9, .

10 numeric keys to input numbers, alphabets or symbols.

ENT

Determines the input.

F1-F3

3 programmable function keys.

* The layout of keys may differ depending on the product specification.

Quick Start Guide

• Read this quick start guide carefully before installing and/or using this product.

• Keep this quick start guide for future reference and store it in a safe place.

Introduction

H-13

Notice

• This quick start guide may be revised or withdrawn at any time without prior notice.

• This quick start guide may not, in whole or in part, be copied, photocopied, reproduced, translated or converted

to any electronic or machine readable form without prior written consent of Opticon.

• Trademarks used are property of their respective owners.

• Under no circumstances shall Opticon be held responsible for any special, incidental, consequential or indirect

damages howsoever caused.

• This quick start guide does not cover programming or the downloading of data. Please contact Opticon or your

dealer for details of these procedures.

Cautions and Warnings

1. Laser Safety

• Do not stare into the laser beam.

2. Handling Instructions

H-13

• Do not attempt to disassemble, modify or update this device.

• Do not use this device near combustible materials.

• Do not store this device in an extremely cold or hot environment.

• Operating the device while operating machinery or a vehicle can be distracting.

• Do not swing the device around by the strap.

• Avoid static electricity.

• Do not drop this product or put heavy items on this product.

• Do not insert a sharp object such as a needle into the buzzer hole.

• Keep the device out of the reach of small children.

• Keep the IrDA communication window clean to avoid communication problems.

• The IrDA communication performance may decline due to excessive ambient light.

• When cleaning this product, rub gently with either a soft dry cloth or a damp cloth with mild detergent.

• Do not use this product in the following areas:

-In areas exposed to direct sunlight for long periods of time.

-Near water or other liquids, or in extremely high humidity.

-In dusty environments.

-Near heat sources, such as radiators, heat registers, stoves, or other types of devices that produce heat.

-Near TVs, microwaves, medical devices, or low-power radio stations.

-In areas where dew condenses.

Battery Pack

• Do not attempt to disassemble this battery.

• Use only the battery specified for this product.

• Do not charge the battery in temperatures less than 0 deg. C or greater than 40 deg. C.

• Do not store the battery in temperatures less than 0 deg. C or greater than 40 deg. C.

Alkaline Battery

• Do not attempt to disassemble this battery.

• Do not short the power leads on the battery. If the (+) and (-) terminals come in contact with metals (such as necklace

or hairpin), a short-circuit will occur.

• Do not load the battery with its (+) and (-) terminals reversed.

• If battery fluid gets in eyes, rinse with water and consult a doctor immediately.

• Check the local regulations for proper battery disposal.

• Do not mix different types of batteries.

• Do not mix old and new batteries.

• Remove the battery if the portable terminal stops operating or if you do not intend to use it for a long period.

(Please refer to the specification manual for details.)

Copyright

©

2008 OPTO ELECTRONICS CO., LTD. All rights reserved.

H-1311-9062-0-02

使用にあたって

Using the Portable Terminal

How to Insert or Exchange a Battery

STEP 3

STEP 2

STEP 1

Please open the battery

cover before inserting or

exchanging a battery.

When using

AA alkaline batteries

STEP

2

STEP

1

Please close the battery

cover.

STEP

3

* Be sure to use only alkaline types when powering the device from batteries. Do not mix old and new batteries.
* Insert the upper part of the battery (BTR0100) first

, and then insert the bottom

as shown in the figure.

No.

Part

Function

LED

Alerts users to the status of program

execution, scanned data and so on.

LCD

Indicates the status of program

execution, scanned data and so on.

SCAN Key

Starts a barcode scanning operation.

POWER Key

Turns the power ON and OFF.

IrDA

Communication

Window

This portable terminal communicates

with the designated cradle through

the IrDA communication window.

Buzzer Hole

Buzzer sounds through the

buzzer hole.

Strap Hook

To attach the strap.

Optical Window

The scan engine emits a laser

beam through the optical window

while scanning a barcode.

⑨ Laser Safety

Laser-related caution stated.

⑩ Product Label
⑪ Battery Cover

Protects the battery pack.

⑫ Battery Cover Lock

Locks the battery cover.

Charging

Terminals

Electrical terminals for power

distribution and power management.

Overview

Detailed View

Key Layout

Charge Function

Charging starts as soon as the H-13 is placed into the cradle (CRD-13) when using the battery pack (BTR0100).

10 numeric

keys

Q1

Q2

SCAN

ENT

Unlock the cover and

slide it forward. Then

remove the cover.

❶Remove the battery bay

and insert 2 AA batteries

into it.

❷Set the battery bay in

the portable terminal.

When using the

battery pack

(BTR0100)

❶Remove the battery bay.
❷Insert the battery as shown

in the figure.

Battery

bay

No.

Item

Product No.

Function

1

Portable Terminal

H-13

A laser portable terminal with a barcode scanning feature.

2

2 AA alkaline batteries

----------------------

Alkaline batteries

3

Strap

B01009-14

Hand strap for H-13.

4

Quick Start Guide

H-1311-9062-0-02

Provides product information and instruction guide.

Before Getting Started

What s in the Box

Confirm that you have the following items before getting started:

* The number of accessories may differ depending on the product specification.

Please contact the nearest dealer if accessories are damaged or missing.

Overview

H-13 Basic Specifications

Designated Cradle

(Optional)*

CRD-13

Communication &

Charging Cradle

Communication Method (Cradle to Host) Communicates with the host via RS-232C or USB interface.
Size

(H)64.9

× (W)70.0 × (D)144.4 mm

Weight

Approx. 125g

Charging Time

Approx. 3 hours

* Please refer to the specification manual or the instruction guide for details of designated cradle.

Parameter

Specifications

Remarks

Physical

Features

Size

(W) 52.8

× (D) 30.5 × (H) 159.0mm

Weight

Approx. 180g (including Alkaline batteries)

Color

Black

Control Section CPU

32bit RISC CPU

External

Memory

FROM

4MB

For OS/AP

RAM

16MB (User Area: Approx. 14MB)

For OS/AP Work Area/ For User DATA

LCD

Section

Material

FSTN semi-transparent LCD

Number of Dots

128 dots

× 128 dots

Dot Size

0.24mm

× 0.24mm

Dot Pitch

0.02mm

× 0.02mm

Backlight

White LEDs

Contrast Control

Enabled

Other

Display

Section

LED

Bi-color LED (Red and Green)

Vibration

Vibrating motor

Buzzer

Tone and loudness can be configured.

Operation

Section

Keys

22 keys: Numeric keys, Trigger key, BS key, Shift key, CLR key, ENT key, PW key,

Up/Down keys, 3 Function keys

Comm.

Section

IrDA

IrDA Ver1.2

Baud rate : (SiR): 9600 to 115.2kbps

(FiR): 4M(bps)

* Theoretical figure (Actual baud rate

may differ from the stated rate)

Clock Section Real Time Clock (RTC) Supports year, month, day, hour, minute, second. (leap year supported)
Power Supply

Section

Main Power Supply Lithium-ion battery (3.7V, 1100mAh)

2 AA alkaline batteries

* BTR0100 (Sold separately)

Backup Power Supply Lithium secondary battery

As RAM/RTC backups

Operating Time

Lithium-ion battery:

Approx. 90 hours (Typ.)

AA alkaline battery: Approx. 150 hours (Typ.)

* When scanning twice evey 10 seconds

at room temperature with a new and

fully-charged main battery.

Data Retention Time More than 7 days

* Data retention time for RAM and RTC at

room temperature when the backup

battery is new and fully charged.

Scanning

Section

Light Source

Red laser diode

Wavelength/Light Output 650 ± 10nm Up to 1mW 25 deg. C
Scan Rate

100

± 20scan/sec

Supported

Symbologies

JAN, EAN, UPC-A, UPC-E, NW-7(Codabar), Industrial 2 of 5, Interleaved 2 of 5, Code 11, Code

39, Code 93, Code 128, MSI/Plessey, UK/Plessey, IATA, Telepen, Matrix 2of 5, S-Code, Tri-Optic,

Chinese Post , EAN 128, RSS-14, RSS Limited, RSS Expanded, PDF417, MicroPDF417

Durability

Operating Temperature -10 deg. C to 50 deg. C
Operating Humidity 20% to 85% (non-condensing)
Storage Temperature -20 deg. C to 60 deg. C
Storage Humidity 20% to 85% (non-condensing)
Charging Temperature 0 deg. C to 40 deg. C
Dust- and Drip-proofing IP54

Shock Endurance

Dropped three times from each of 6 angles onto concrete from a height of 150cm with no

defects found. (Total: 18 times)

・Charging takes about 3 hours to fully charge an

empty battery.

Memo

Charging Indicator Status Color

Charging Status

Cradle LED

Green Charging the H-13

H-13 LED

Red

Charging

Green Charging complete

Cradle LED

Green : Charging

the H-13

Red: Charging

Green : Charging complete

H-13 LED

POWER

Advertising