Opticon M5 User Manual

Quick start guide

Advertising
background image

M-500009062-0-00

The Netherlands Opticon Sensors Europe B.V.

tel: +31 (0)23-5692700

/ email: [email protected]

U.S.A.

Opticon Inc.

tel: 800-636-0090

/ email: [email protected]

France

Opticon S.A.S.

tel: +33 (0)1-41461260

/ email: [email protected]

Germany

Opticon Sensoren GmbH

tel: +49 (0)6074-91890-0

/ email: [email protected]

Italy

Opticon s.r.l.

tel: +39 (0)051-6321800

/ email: [email protected]

Spain

Opticon Sensores S.L.

tel: +34 (0)902-747469

/ email: [email protected]

Contact

Sweden

Opticon Sensors Nordic AB

tel: +46 (0)8-58548560

/ email: [email protected]

United Kingdom Opticon Limited

tel: +44 (0)1582-635100

/ email: [email protected]

Taiwan

Opticon Far Eastern Ltd.

tel: +886 2-27597444 / email: [email protected]

China

Opticon Sensors Europe B.V., Shanghai Representative Office

tel: +86 21-64480881

/ email: [email protected]

Australia

Opticon Sensors Pty. Ltd.

tel: +61 (0)2-43402666

/ email: [email protected]

Brazil

Opticon Sensors Europe B.V., Latin American Office

tel: +55 11-5081 2088

/ email: [email protected]

Please contact OPTICON or your local dealer.

More product details, additional support, and configuration options (from the Universal Menu Book) are available at www.opticon.com.

Notice

• This quick start guide may be revised or withdrawn at any time without prior notice.

• This quick start guide may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any

electronic or machine readable form without prior written consent of Opticon.

• Trademarks used are property of their respective owners.

• Under no circumstances shall Opticon be held responsible for any special, incidental, consequential or indirect

damages howsoever caused.

Precautions for Use

1. LED Safety

Do not stare into the LED s.
2. Handling Instructions

M-5

• Do not attempt to disassemble, modify or update this device.

• Do not use the scanner while operating machinery.

• Do not drop or put heavy items on this product or its cable.

• Do not pinch or forcibly bend the cable, especially at very low temperature.

• Do not insert foreign substances into the device.

• Do not use/leave this device:

- In areas exposed to direct sunlight for long periods of time

- In dusty environments

- In risk for an exposure to chemicals

- Near water or other liquids, as well as in extremely high humidity

- Near heat sources such as radiators, heat registers, stoves, or other types of devices that produce heat

- Near microwaves, medical devices, or RF-emitting devices

- In the reach of blinking lights such as CRT

• Do not use this product during a lightning storm.

AC/DC Adapter

• Use only the supplied AC adapter with the enclosed region specific plugs for connection to the wall socket.

• This product may produce heat when in use, but it does not affect its performance.

• Do not pull on the cord when unplugging the power cord from a power outlet. Grasp the plug to remove it.

• Do not plug in or out this product with wet hands.

• Unplug this product when it is not in use or when it is being cleaned.

Quick Start Guide

Introduction

M-5

Copyright

©

2009, Opticon All rights reserved.

                      

Setting Menu Codes

The M-5 can be configured by reading the menu codes below. Read more about configuration options

(by Opticonfigure) on www.opticon.com.

Detailed View

Overview

M-5 Basic Specifications

Parameter

Specifications

Physical

Features

Size

(H)140.0

×

(W)92.0

×

(D)95.5 mm

Weight

Approx.295g (excluding the cable)

Operation

Section

Scan Confirmation Buzzer and 3 colors LED(Green/Blue/Orange)
Keys

2 keys (Trigger Switch/Mode Switch)

Interfaces RS-232C

9600bps

115.2kbps

USB

Full-Speed 12Mbps(HID/VCP)

Hi-Power Bus-powered

Wedge

PS/2 Keyboard (Connect or disconnect the keyboard.)

Control

Section

ASIC

OEY-0603 CPU:ARM-1026EJ-S Core:160MHz

SDRAM

128Mbits(1M

×

4Banks

×

32Bits)

Flash ROM

16Mbits(1M

×

16Bits) Flash Memory

Scanning

Section

Light Source

Wavelength

8-AllnGaP Red LEDs(Omniscan Mode)/625nm

4-AllnGaP red LEDs (Mobile Mode)/633nm

Scanning Method WVGA(752 x 480 pixels) CMOS area sensor

Supported

Symbologies

(1D)

UPC-A,UPC-E, UPC-E1, UPC-A Add-on, UPC-E Add-on, EAN-13,

EAN-8, EAN-13 Add-on/EAN-8 Add-on, JAN-8 , JAN-13, Code

39,Tri-Optic, NW-7, Industrial 2 of 5, Interleaved 2 of 5, Code 93,

Code 128, GS1-128, S-Code, MSI/Plessey, UK/Plessey, TELEPEN,

Matrix 2 of 5, Chinese Post Matrix 2 of 5, IATA,Code 11,

Korean Postal Authority code , GS1 DataBar, Postal Code

Supported

Symbologies

(2D)

PDF417,MicroPDF417,QR Code,MicroQR Code,Data

Matrix (ECC 000-140/ECC 200),MaxiCode (Modes 2 to 5),

Aztec Code, EAN.UCC Composite bar code, Codablock F

Power

Supply

Section

Operating voltage 4.5 to 6.6V

Current

consumption

USB

RS-232C, Wedge

Peak

(when scanning and decoding)

420mA

400mA

Average

(when scanning and decoding)

280mA

(typ)

210mA

(typ)

Stand-by

140mA

(typ)

130mA

(typ)

Durability Operating Temp. 0 to 40 deg. C

Storage Temp.

40 to 70 deg. C

Operating Humidity 5 to 95

(non-condensing)

Storage Humidity 5 to 95

(non-condensing)

Ambient

Light

Immunity

Fluorescent

10,000lx or less

Incandescent lamp

10,000lx or less

Sunlight

50,000lx or less

(

*

1)

Dust-and-Drip Proof IP52
Static Electricity 15kV (no destruction)

Shock

Endurance

Dropped once from each of 5 angles onto

concrete floor from a height of 150cm with

no defects found. (Total 5 times)

No.

Part

Function

Optical Window

Trigger Switch

The trigger switch is used for the manual

scanning operation. A single aiming guide

will be activated in this mode.

Mode Switch

The mode switch toggles between Mobile phone

scanning mode and Normal scanning mode.

Indicator LED

Green LED light shows the scanning

operation has been successful.

Blue LED light shows when the scanner is

ready to scan.

Indicator LED While Mobile

phone scanning Mode

Orange LED light shows when the scanner

is ready for mobile code scanning.

Buzzer Holes

Screw Holes

Used to mount the scanner onto a base plate,

wall etc. using D4 (diameter: 4mm) screws.

Before Getting Started

No.

Item

Function

Notes

1

Scanner

An omnidirectional imaging scanner

2

Interface cable

A cable for connecting the scanner

Different for each interface spec.

3

Wedge branch cable

Y-cable: The cable that can be used to connect a keyboard

and the scanner's straight cable to a host computer.

Only for Wedge interface.

4

Connector cover

A cover used to fix the connection between the

Y-cable and the straight cable.

Only for M-5-WEDGE+PS package.

5

Instruction of connector cover An instruction manual for the connector cover

Only for M-5-WEDGE+PS package.

6

AC adapter

AC adapter with interchangeable plugs

Only for RS-232C and Wedge interface.

7

Interchangeable plugs

Plugs for different regions

Only for RS-232C and Wedge interface.

8

Quick start guide

This manual provides the basic product specification

and setup instructions.

What's in the Box

Confirm that you have the following items before getting started. Please note that the contents may differ

depending on interface specifications. Please contact the nearest dealer if items are damaged or missing.

Various Scanning Modes

The following modes are available for different uses:
□ Normal scanning mode

A mode in which the scanner is configured optimally for general barcode

reading. The device automatically starts scanning when a label is
held in front of it. The trigger key activates the single line scanning.

□ Mobile phone scanning mode

A special mode

― in which the lighting conditions are optimized for

reading barcodes,

― displayed on mobile devices such as a phone.

The device automatically starts scanning when a label is held in front
of it. The trigger key activates the single line scanning.

□ Single line scanning

While the trigger switch is pressed, the illumination LEDs turn on

and only one code can be read. The single line can read one target

code out of multiple printed codes in this mode.

                      

Setting Menu Codes

(*1)Except Mobile phone scanning mode in each condition. Please note that scanning while the

LCD screen is exposed to direct sunlight may have a negative effect on the reading performance.

Figure 1. Scanning mode diagram

Normal scanning

mode

Mobile phone

scanning mode

Mode Switch

Power

ON

Single line

scanning

Trigger

Switch

Finished Scanning

or Time-Out

Basic Specifications for Universal AC adapter

Parameter

Specifications

Physical

Features

Size

(H)75 x (W)47.5 x (D)28mm (excluding boss)

Cable Length

1.8m

Colour

Black

Input

Power Voltage AC 90V to 265V
Supply Current 500mA Max

Output

Power Voltage 5.7V to 6.3V
Maximum Current 2A Max

Environmental

Specification

Operating Temp. 0 to 40 deg. C
Operating Humidity 25 to 85% (non-condensing)
Storage Temp.

20 to 60 deg. C

Storage Humidity 20 to 90% (non-condensing)

Trigger

Switch

Finished Scanning

or Time-Out

: Default

Default Setting

Enable QR Code

(* Use this only when Disable QR Code is set in advance.)

Start / END: ZZ

Enable QR Code: BCD

Stop / END: ZZ

Back to default

Serial command :

U2, C01, SU, UB

"Normal scanning mode" or "Mobile phone scanning mode"

can be selected as primary mode when the scanner starts up.

Scanning Mode Setting

Normal scanning mode

Serial command :

E8Y

Mobile phone scanning mode

Serial command :

E8Z

Auto trigger ON / OFF can be set. When it is set to OFF, only

the trigger switch can be used to activate the scanner.

Auto Trigger Setting

Auto Trigger OFF

Auto Trigger ON

Serial command :

+I

Serial command :

+F

You can set the time that the scanner will try to read a code

after it is detected by the auto trigger. This can be set for Nor-

mal scanning mode and Mobile phone scanning mode .

For single line scanning, it can be set as the LED aiming time.

Read Time Setting

Normal scanning mode

Serial command :

Y0 (0.5s) Serial command : Y2 (2.0s)

Serial command :

Y1 (1.0s) Serial command : Y3 (3.0s)

Mobile phone scanning mode

Serial command :

E91 (1s)

Serial command :

E93 (3s)

Serial command :

E92 (2s)

Serial command :

E94 (4s)

Single line scanning

Serial command :

E8V (1s)

Serial command :

E8X (5s)

Serial command :

E8W (3s)

• Read this quick start guide carefully before installing and/or using this product.

• Keep this quick start guide for future reference and store it in a safe place.

 

The time that a code will not be read after it is read successful

once can be set. This can prevent the double read of a code.

Multiple read reset time Setting

Multiple read reset time

Serial command :

AJ (200ms)

Serial command :

AK (300ms) Serial command : E9I (800ms)

Serial command :

E9H (700ms)

Serial command :

AL (400ms)

Serial command :

AN (600ms)

Serial command :

E9J (900ms)

Serial command :

AG (Infinity)

Serial command :

AM (500ms) Serial command : E8T (1s)