Opticon OPN 2001 Device Parameters User Manual

Page 2

Advertising
background image

Opticon OPN2001 User Parameters

Page 2 of 3

There are no barcode changeable parameters in the OPN2001; they are only changeable by host command.

Parameter

Comments

Min/Max Values

Default

Param Num

Buzzer

1=Enable

0=Disable

Enabled

2 (0x02)

Reject Redundant

Barcode

Disabling will allow same

barcode to be stored

consecutively.

Mode 1 means that a code is

allowed only if the previous code

is not the same.

Mode 2 means that a code is

allowed only if none of the

previous codes are the same.

2=Enable mode 2.

1=Enable mode 1.

0=Disable

Disabled

4 (0x04)

Low-Battery Indication

Determines how low battery

condition will be handled.

0=No operation

1=Ignore low battery

2=Indicate, but laser

stays off

3=Indicate, operate

normal otherwise.

3

7 (0x07)

Code128

1=Enable

0=Disable

Enabled

8 (0x08)

UPC & EAN

1=Enable

0=Disable

Enabled

9 (0x09)

Host Connect Beep

1=Enable

0=Disable

Enabled

10 (0x0a)

Host Complete Beep

1=Enable

0=Disable

Enabled

11 (0x0b)

Auto Clear

Clear barcodes after upload.

1=Enable

0=Disable

Disabled

15 (0x0f)

Scanner

On-Time

1 sec. – 10 sec. in 100

msec increments

30 (3.0 sec) 17 (0x11)

RSS code

0 = Disable

1 = RSS Limited

2 = RSS 14

4 = RSS Expanded

(Options can be

combined)

0

20 (0x14)

Good Decode LED On

Time

250 ms. – 1 sec. in

250msec. Increments

4

(1.0 sec)

30 (0x1e)

Code 39

1=Enable

0=Disable

Enabled

31 (0x1f)

Delete Enable

Determines operation of the

Delete key, the Clear All and Set

All Default functions.

Bit 0 = Clear all

Bit 1 = Delete key

Bit 2 = Set all Default

e.g. 5 = Clear all enabled,

Set all Default enabled,

Delete key disabled.

7 =

Delete

Enabled

Clear All

Enabled

Set Default

Enabled

33 (0x21)

Max Barcode Len

1 – 30

30

34 (0x22)

Store RTC timestamp

Store Real Time Clock data

1=Enable

0=Disable

Enabled

35 (0x23)

Advertising