Wire antenna deployment assembly model 9842, Typical technical specifications: introduction

Advertising
background image

Wire Antenna
Deployment
Assembly
Model 9842

Wire Antenna
Deployment
Assembly
Model 9842

Typical Technical Specifications:

Introduction

Wire Antenna Deployment Assembly (WADA) Model
9842 was developed for the International Solar
Terrestrial Physics (ISTP) program’s WIND satellite – WAVES
experiment. This motorized mechanism is
capable of extending and retracting a wire antenna up to
360.8 feet (110 meters) long, perpendicular to the satellite
spin-axis. The antenna is a stranded beryllium-copper wire
measuring 0.015 inch (0.038 cm) diameter, with a
tensioning tip mass attached to the outer end. Either bare
or insulated wire may be used. The deployer features

electrical and mechanical stops at both full-extension and
-retraction. A potentiometer, driven by the moving antenna
wire, provides a continuous indication of the deployed
length. This deployment mechanism is designed to meet
the requirements of document MIL-A-083577A (USAF) for
Moving Mechanical Assemblies for Space and Launch
Vehicles. Similar units were used on Dynamics Explorer-1
& 2, International Sun-Earth Explorer, San Marco D/L &
the Combined Release & Radiation Effects Satellite. This
unit can be deployed or retracted in orbit.

Antenna Wire

Deployed Length:

Up to 360.8 ft

(110 meters)

Diameter

W/out insulation:

0.015 in

(0.038 cm)

With insulation:

0.032 in

(0.081 cm)

Material &
Construction:

Beryllium

Copper

Insulation Material:

Teflon

(per MIL-W-
16878)

Weight

W/out insulation:

0.361 gr/ft

(1.184 gr/m)

With insulation:

0.605 gr/ft

(1.985 gr/m)

Deployer

Height:

7.21 in (18.31 cm)

Length:

14.96 in (38 cm)

Width:

7.50 in (19.05 cm)

Total Unit Weight:

5.51 lbs (2.5 kg)

Drive Motor:

Brushless D.C.

Power:

14 Watts maximum

Voltage:

24-32 Vdc

Deployment Rate:

Approximately

1.2 in/sec
(3.05 cm/sec)

Tip Mass:

10 ± 0.1 gram

Operating
Temperature Range: -10°C to +50°C
Qualification
Temperature Range: -20°C to +60°C
Survival
Temperature Range: -25°C to +65°C

Advertising