Specifications, Using an entry confirmation button – Paxton OEM PROXIMITY Long range reader - EM4100 - Wiegand Output User Manual

Page 5

Advertising
background image

11V DC

14V DC

1 A

11V DC

14V DC

80 mA

119 kHz

140 kHz

2.405 GHz

2.480 GHz

26 bits

Belden 9540

100 m

0.75 mm sq

mm sq

2.5 mm sq

5000 mm
2000 mm

P200

2500 mm

P50

1100 mm

- 20 °C

+ 55 °C

IPX67

220 mm

220 mm

120 mm

Specifications

Voltage - Reader module

Wiegand format

Carrier frequency

Operating temperature

Electrical

Environment

Dimensions

Min

Max

Width

Height

Depth

Current - Reader module

P200E metal mount

Cable type for extensions
Cable length between ACU and reader

Read range with hands free token

Waterproof

Additional power supply required

Outdoor Use

Button confirmation input

Yes

Yes

Long range reader

Min

Min

Max

Max

Using an entry confirmation button

Where two door readers may pick up the same hands free token, a push to make button can be used to confirm

an entry request for the specific door. Where fitted, the button LED will flash for 5 seconds after the hands free

token has been recognised and must be pressed to unlock the door.

To enable the use of an entry confirmation button do the following steps:

1. Power down the interface board

2. Power up the interface board

3. Press and hold the entry confirmation button for a minumum of 3 seconds within 60 seconds of power up.

To disable the use of the button, repeat the above process.