WHITE labelled control units provide 5V at the Red terminal. The Red power wire

for the reader should therefore be directly connected to the 12V supply terminal.

Wiring

Cable extensions

Readers can be extended using Belden CR9540 10-core overall screened cable to a maximum of 100 metres.

The reader port module is designed to convert the

standard reader ports on Switch2 and Net2 controllers

to accept one or two RJ45 connections. Pull off the

screw terminal block from the reader port and simply

replace it with this module.

This module can be used to provide a

connection point for the reader RJ45 plug.

The terminals on the module are then wired

colour for colour to the controller.

Alternatively, the reader can be wired directly

into the screw terminals of the control unit by

first cutting off the RJ45 plug and stripping

back the wires in the cable.

Reader port module (325-030)

This module may be purchased separately to speed

up the installation and replacement of readers.

Connection modules

Further information on how to purchase Installer Tools is available at:

http://paxton.info/841

Reader junction box (325-020)

This reader is designed to read Paxton Tokens (Hitag2) and EM4100 tokens.

Connection to a control

unit reader port