Revision history – PLX Devices SM-AIT User Manual

Page 4

Advertising
background image

Users Guide: iMFD Sensor Module

Version 1.0 July 11, 2007

www.plxdevices.com

(408)745-7591

Specifications:

Physical Dimensions

2" x 2.875" x 1.125" (52mm x 75mm x 28mm) L x W x H

Accuracy

+- 0.5 Deg C (+- ~1 Deg F)

Measurement Range

0-333 Deg C (32-631 Deg F)

Analog Outputs

Linear 0-5V (Driving Current 20mA) *Output is capped at 3.3V

Operating Voltage

8V-18V

Power Consumption

0.3 Watts

Operating Temperature

0 - 85 Deg C

Sensor

One K-Type Thermocouple

Enclosure Extruded

Aluminum

TERMS OF USE

PLX Devices Inc. does not guarantee the Sensor Module functionality with any ECU, data logger or other devices that uses the output
signals. Implementation and integration of the Sensor Module with any other device(s) must be done at your own risk. Improper
installation and usage may lead to engine damage. Mount and install the Sensor Module in a location where it does not obstruct the
driver’s view and/or ability to safely control the vehicle.

LIMITED WARRANTY

PLX Devices Inc. warrants this product to be free from defects for 90 days from the date of purchase. If applicable, Oxygen sensors
and other non-serviceable items are excluded from stated warranty. Serviceable goods must be determined by PLX Devices to be
defective before any warranty or replacement is issued. PLX Devices’ obligation under warranty shall be limited to repairing or
replacing, under the discretion of PLX Devices, any part proven defective. This warranty is limited to the repair or replacement of
parts in the manufactured good and the necessary labor done to affect its repair or replacement.

SERVICE UNDER WARRANTY

In the unlikely event that your PLX Devices hardware should fail during the warranty period, a Return Material Authorization number
(RMA) must be first retrieved from PLX Devices Customer Support. Support can be contacted through email:

[email protected]

or by phone: 408-745-7591. All serviceable goods must be packaged securely with proof of purchase, RMA number, with all shipping
charges prepaid and shipped to PLX Devices Inc. Goods returned under warranty must be received by PLX Devices Inc. within ten
(10) business days after the RMA number has been issued. Goods received after this period is subject to fees for the service of repair
or replacement. All repaired or replaced items shall be warranted for the remainder of the original product warranty.

RETURNS AND RESTOCKING FEE

A 15% restocking fee will apply to applicable PLX Devices products for refund. All returns are to be packed in original condition
including packaging, documentation, manuals, and accessories. Returns that do not include all the accessories and components may
be returned to the customer or charged on a per item basis. The customer assumes responsibility for product until receipt at PLX
Devices Inc., shipping via an insurable carrier is recommended. Any unauthorized shipping charges will be billed to the customer or
shipment will be refused.

DISCLAIMER

PLX Devices Inc. shall not be liable for direct, special, incidental, or consequential damages resulting from any legal theory including,
but not limited to, lost profits, downtime, goodwill, damage, injury to persons, or replacement of equipment and property due to
improper installation, integration and/or misuse of any PLX Devices Inc.’s product(s). This warranty applies to the original purchaser
of product and is non-transferable. All implied warranties shall be limited in duration to the said 90 day warranty period.

Revision History

Version 1.0 (7/11/07)

Initial release

Advertising