Piecal 134 operating instructions, Ez-check, Switch – Practical Instrument Electronics 134 User Manual

Page 2: Source mode, Wire transmitter simulation mode

Advertising
background image

PIECAL 134 Operating Instructions

82 E. Main Street Suite 3.14 · Webster, NY 14580

Tel: 585-872-9350 · Fax: 585-872-2638

[email protected] · http://www.piecal.com/

Practical Instrument Electronics, Inc. Copyright ã 2011. All rights reserved.

531-9002 Rev B 7/13/11

2-4

EZ-Check

Switch

The EZ-Check™ switch has three positions -- high, dial, and low. Its position is shown at the left edge of the display with “HI” and

“LO” indicators. Neither indicator indicates the middle position. Use of the EZ-CheckÔ switch depends on mode.

Source Modes:

Slide the EZ-CheckÔ switch to the HI and LO positions to recall the preset settings (Hi=20.00mA & Lo=4.00mA).

Hint: For faster calibrations, the position of the switch can be felt. This feature allows continuous monitoring of the device

being calibrated without looking back at the PIECAL 134 display. This is also useful in poor lighting or under difficult

operating conditions.

Read Modes:

In read mode, the PIECAL 134 calibrator records the maximum and minimum readings observed in each mode. Slide the

EZ-CheckÔ switch to the Dial position to read the loop. Then Slide the EZ-CheckÔ switch to the HI and LO positions to
display the max and min readings. Press

EZ-Dial

Ô knob

to clear the readings. The display will flash “CLEARED” to

confirm.

Source Mode


Source mode uses internal power to supply current from 0.00-24.00 mA into as much as 1200Ω until the end of battery life. The

calibrator Graph will flash if connected improperly. The three-position EZ-Check switch provides instant preset 4mA at zero, 12mA at

mid range and 20mA at full scale outputs. The output is adjusted in 0.01 or 0.10 mA increments (0.1 or 1.0) % display units with

the EZ-Dial knob.

2-Wire Transmitter Simulation Mode


The PIECAL 134 can simulate a 2-wire transmitter in the 4-20 mA or % process loop. In source mode press the EZ-Dial™ Knob twice

to get into the feature options. Then press the EZ-Dial™ Knob to select mA 2 – wire. The EZ-Check switch and EZ-Dial knob allow

rapid and fine control of loop current.

T

r

a

n

s

m

i

t

t

e

r

I

n

p

u

t

(

S

e

n

s

o

r

)

(

P

r

o

c

e

s

s

S

i

g

n

a

l

)

(

S

i

m

u

l

a

t

e

d

I

n

p

u

t

)

R

e

c

e

i

v

e

r

P

o

w

e

r

S

u

p

p

l

y

0

t

o

6

0

V

D

C

T

y

p

i

c

a

l

2

-

W

i

r

e

T

r

a

n

s

m

i

t

t

e

r

+

I

N

-

R

E

F

+

O

U

T

-

T

r

a

n

s

m

i

t

t

e

r

I

n

p

u

t

(

S

e

n

s

o

r

)

(

P

r

o

c

e

s

s

S

i

g

n

a

l

)

(

S

i

m

u

l

a

t

e

d

I

n

p

u

t

)

R

e

c

e

i

v

e

r

P

o

w

e

r

S

u

p

p

l

y

0

t

o

6

0

V

D

C

T

y

p

i

c

a

l

2

-

W

i

r

e

T

r

a

n

s

m

i

t

t

e

r

+

I

N

-

R

E

F

+

O

U

T

-

Advertising