The_initial_calibration, Interpreting_replay_graphs – Precision Turbo and Engine BigStuff3 GEN3 Engine Torque Management (ETM) System User Manual

Page 10

Advertising
background image

The Initial Calibration

(READ BEFORE USING THE SYSTEM)

:

• Make sure the driveshaft speed sensor is installed and functioning correctly.

Disable the Torque Management system w/

ETM_Disable

. Make sure the box titled “Torque

Control Enable”, in the Torque Parameters table is not checked. See Torque Parameters screen
print above.

• Following the “How to Use the ETM System procedure directly above, collect data from a pass.

• In the

Desired_Driveshaft_Table

, input desired driveshaft speed values 200 RPM greater than

the actual driveshaft speed data collected in the initial pass.


Interpreting ETM Replay Graphs

Timer enable
“on” starts the
timers.

User inputted
TISS curve

Actual driveshaft
speed or TOSS
value

Rev

1.1

10