Advertising
background image

Form # 147141

Issue 02/06 Web Rev_01

117

TROUBLE SHOOTING


SYMPTOM

PROBLEM

SOLUTION

REF.

Air conditioning not
producing sufficient
cooling (continued).

Clogged expansion
valve.

Recover system
refrigerant and replace
valve. Then, evacuate
and charge system.

*

Clogged receiver-drier.

Recover system
refrigerant and replace
receiver-drier. Then
evacuate and charge
system.

*

Excessive moisture in
system.

Recover system
refrigerant and replace
receiver-drier. Then
evacuate and charge
system.

*

Air in system.

Recover refrigerant,
evacuate and charge
system.

*

Thermostat defective or
improperly adjusted.

Replace thermostat.

*

Blower motor sluggish
in operation.

Remove motor for
service/replacement.

*

Air conditioning system
too noisy.

Defective winding or
improper connection in
compressor clutch coil
or relay.

Repair or replace as
necessary.

*

Loose or excessively
worn drive belt.

Tighten or replace as
required.

66

Noisy clutch.

Remove clutch for serv-
ice or replacement as
required.

*

Noisy compressor.

Check mountings and
repair. Remove
compressor for service
or replacement.

*

Compressor oil level
low.

Add SP-16 PAG refrig-
erant oil.

*

Blower fan noisy due to
excessive wear.

Remove blower motor
for service or replace-
ment as necessary.

*

Excessive charge in
system.

Discharge excess
refrigerant until pressure
drops within specs.
(Always recover
discharged refrigerant.)

*


Low charge in system.

Check system for leaks,
charge system.

* See your Windrower dealer.