D50 & D60 HEADER/ADAPTER

Form 169009

43

Model Year - 2009

e. Lower stand (F) by pulling spring loaded pin

(G). Release pin when stand at desired height.

f. Remove pin (H) from leg on both sides of

adapter.

g. Disconnect center link as follows:

1. For hydraulic adjuster, lift release (J) and

latch it in up position.

2. Extend center link cylinder to disengage

hook from header.

3. Prop up center link with a pin or equivalent

tool.

4. For mechanical link, remove pin (K) to

release link. Replace pin.

NOTE

Feeder house may need to be raised or
lowered, or length of link adjusted, to
relieve load on link.

h. Disconnect sickle and draper drive hydraulic

hoses. Install caps and plugs on fittings.

i. If quick disconnects are installed, disconnect as

follows:

1. Line up slot (L) in collar with pin (M) on

connector.

2. Push collar toward pin and pull connector to

disengage.

3. Install plugs or caps on hose ends (if

equipped).

j. Disconnect electrical connector by turning collar

counterclockwise and pulling connector to
disengage.

k. Store and secure hoses on adapter.

(continued next page)

K

M

L

J

DRAPER DRIVE

RETURN

ELECTRICAL

KNIFE DRIVE

CASE DRAIN

(DOUBLE KNIFE)

QUICK DISCONNECTS SHOWN

F

G

H